FDC 4 Скачать руководство пользователя страница 1

DEFRA Clean Air Act Exemption 

 

The 

FDC 5

FDC 5W

 & 

FDC 8

 stoves only have been exempted under the Clean Air Act 1993 

to burn seasoned wood logs in designated smokeless zones in the UK. This is subject to the 
correct fitting of the air control plate (the part and fitting instructions are supplied separately) 
maintaining the air wash control at a minimum opening at all times

. Instructions for wood 

burning MUST be followed in order to ensure compliance at all times.

  

 
 

 

 

FDC 4, 5, 5 Wide & 8 FREESTANDING 

STOVE RANGE 

 

4, 5, 5 & 8 kW Nominal Outputs 

 

With Patented 

TTi

 Air System  

 

Installation and Operating 

Instructions 

 

Please hand these instructions to the stove user when the installation is complete. 

Leave the stove ready for operation and instruct the user in the correct use of the 

appliance and operation of controls. 

 

Important: 

– 

These products must be installed by a suitably 

qualified installer. 

 

FDC (UK) LIMITED 

Unit C4, Dinton Business Park 

Catherine Ford Road 

Dinton, Salisbury 

WILTSHIRE 

SP3 5HZ 

T

: 01722 716 161 

F

: 01722 716 162 

e

[email protected]

 

  

Содержание 4

Страница 1: ...n order to ensure compliance at all times FDC 4 5 5 Wide 8 FREESTANDING STOVE RANGE 4 5 5 8 kW Nominal Outputs With Patented TTi Air System Installation and Operating Instructions Please hand these in...

Страница 2: ...lation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Hearths 6 4 7 Commissioning Handover 6 5 Technical Data Declaration of...

Страница 3: ...t of Components section and check contents carefully 2 1 To remove the baffle plate first remove the two stainless steel side firebox liner clips by lifting them above the fuel retainer Remove the two...

Страница 4: ...nd BS EN 15287 must be fulfilled The installation is a notifiable building works as defined in the building regulations and that it is a legal requirement under England and Wales Building Regulations...

Страница 5: ...possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment 3 1 11 Metal Parts When installing or servicing this...

Страница 6: ...tted be used on the FDC 5 5W models ONLY providing that they only burn smokeless fuel or seasoned wood logs with the air limiter fitted in in full accordance with the wood burning instructions An exis...

Страница 7: ...nding stoves do not require a constructional hearth beneath them as they do not cause the floor temperature to exceed 100 degrees C Note the optional solid fuel hearth heat shield MUST be fitted when...

Страница 8: ...and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use of the appliance wit...

Страница 9: ...5 FDC 5W FDC 8 Domestic Heating Appliances Appliance gross weight packed Kg 54 70 74 81 Harmonized Test Standard EN13240 2001 Amd 2 2004 Quality Constancy Standard ISO9001 Test Report Issue No 6546 2...

Страница 10: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Страница 11: ...the pointed part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that...

Страница 12: ...ill then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes o...

Страница 13: ...open the secondary air wash control fully Then load the firebox with plenty of starting fuel i e paper dry kindling sticks and or firelighters If using Ancit place a layer of ancit into the firebox a...

Страница 14: ...the controls are left in this position the fire will eventually go out If you want to revive the fire it is recommended that the primary air controls are open first and then open the secondary air co...

Страница 15: ...Open doors and windows to ventilate room and then leave the premises 2 Let the fire out or remove and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required...

Страница 16: ...15 FDC 4 5 5W 8 Issue 05 10 14 8 1 FDC 4 Stove Dimensions...

Страница 17: ...16 FDC 4 5 5W 8 Issue 05 10 14 8 2 FDC 5 Stove Dimensions...

Страница 18: ...17 FDC 4 5 5W 8 Issue 05 10 14 8 3 FDC 5W Stove Dimensions...

Страница 19: ...18 FDC 4 5 5W 8 Issue 05 10 14 8 4 FDC 8 Stove Dimensions...

Страница 20: ...ur local Stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact FDC direct 7 Can the doors be left open while burning For safety an...

Отзывы: