FCI WATERMAKERS, INC.
35
Installation
SYSTEM INSTALLATION / PLUMBING
(continued)
Filter Assembly Outlet
(Tube B)
·
Connects to Panel at “Feed from Filters”
·
Pre-Configured with 1/2" PE Tubing and Fittings
(fittings are reuseable if need to remake with longer tube)
Filter Assembly Inlet
(Hose A)
·
Connects from Dockwater Source
·
Use 3/4" Helix Wire Suction Hose
and Clamps
Front of Filter Assembly
To Vessels
(Tube C)
·
Connects to PV Vessel Flow In
·
Use 3/8" 250psi PE Tubing
Right-Side of Panel
Pressure Vessel Sets
Reject Discharge
(Tube F)
·
Connects to Reject Discharge Fitting
(installed above sea level)
·
Use 1/2" PE Tubing
and 1/2" Tube Connector from Install Kit
Product to Tank
(Tube G)
·
Use 3/8" 125psi PE Tubing
and 3/8" Tube Connector from Install Kit
Feed from Filters
(Tube B)
·
Connects from Filter Assembly Outlet
·
Pre-Configured with 1/2" PE Tubing and Fittings
(fittings are reuseable if need to remake with longer tube)
From Vessels
(Tube D)
·
Connects from PV Vessel Reject Out
·
Use 3/8" 250psi PE Tubing
Product Inlet
(Tube E)
·
Connects from PV Vessel Product Out
·
Use 3/8" 125psi PE Tubing
2,000 GPD Rated System
(P/N 93-5414)
3,000 GPD Rated System
(P/N 93-5414)
Flow In
(Tube C)
·
Connects from Panel, "To Vessels"
·
3/8" 250psi PE Tubing
Product Out
(Tube E)
·
Connects to Panel, "Product Inlet"
·
3/8" 125psi PE Tubing
Reject Out
(Tube D)
·
Connects to Panel, "From Vessels"
·
3/8" 250psi PE Tubing
1
2
3
3
3
1
1
2
2
- or -
Figure 14: Plumbing Connections
Содержание DOCKSIDE TREATMENT SYSTEM PLUS Series
Страница 1: ...DOCKSIDE TREATMENT SYSTEM PLUS SERIES USER MANUAL INSTALLATION GUIDE...
Страница 2: ......
Страница 78: ...FCI WATERMAKERS INC 78 Revision History NOTES...
Страница 79: ......