Содержание XL-2S Silver

Страница 1: ... XL 2S Hookup and Installation Instructions Version 3 0 FBI t FIRE BURGMRY INSTRUMENTS INC Subsidisy of Wtiay Corp 149 Hleen Way Syosset NY 11791 N9513V1 4 96 ...

Страница 2: ...mer and backup battery voltages are supplying the proper voltage levels Verify your programming information Read this manual thoroughly Consult the Troubleshooting Section of this Manual Note the roper model number of this product and the version level of known along with any F documen abon that came with the product Have your company name and telephone number ready This information will allow us ...

Страница 3: ...ck Telephone Nnmber 23 04 Dialer Options 23 05 KeWad Cmrditions 25 06 System Timemrts 28 07 Misc System Options 29 08 Accmrnt Number l 3O 09 Account Number 2 3l ZO PROG G 3l 10Zone Number l 33 llZone Number 2 33 12Zone Number 3 33 13Zone Number 4 33 14Zone Number 5 33 lSZmre Nmnber 6 34 16ArnbusMAC Loss 34 17Panic w Battery 34 180petiClose CS Test 34 19BypassRestore rouble Cancel 34 20 Ke ad FireK...

Страница 4: ...Ring Detect program quest 07 Exit Error Warning always enabled Restore Follows Bell or Loop program quest 05 Bypass InStay Any Controlled Zone can be Bypassed In Stay Mode program quests l O 15 S stem Stabilization on Power Up to Eliminate dtion Detector FalaeAlarms Quick Commands Quick Arm Quick Forced Arm Quick By ass enabled separately program quest 05 XI 2S FFATURF CHANGFS System Wide Restora ...

Страница 5: ...riptors NOT defaulted Stay lnatant Enable moved to program quest W5 location 2 Ueer 5 Arm Onl Enable moved to program quest 05 localon4 Burgla Bell Tfigger Type entry in progrem 7 quest 7 Iocabon 4 la dlgtt 3 CS Test Enable in pro ram queet 04 location 4 P deleted CS Test diseb e edded to CS Test Time m program quest 07 location 3 Inetaller Code Default changed to 246V Xl 2S ver 2 0 S IMILAR FEATU...

Страница 6: ...ter zone descriptors Upload Download with remote mmmands with answering machine bypass Unattended and On line Downloading Default Lockout option to prevent hostile account takeovers Quick arming Quick Forced Arming and Quick Bypass option Indications on keypad for AC loss Low Batte and Communication Failure Central Station reportin for Alarms Troubles Restores Bypasses Openings Closings Ambush Pan...

Страница 7: ...n 10 eece andlor the LCD keypad e will display STAND BY for approximately 2 min 10 aece This occurs on a total powerup eyatem reset or after completion of syetem programming If the total system power ia lost then upon power restorsl the system will return to the previolla erming state The 2 min 10 aeca interval ie ueed to allow motion detectors nterior zones to stakdlize on power up in order to pr...

Страница 8: ...activation of the keyswitch will arm and disarm the system NOTE E O L resistor is not required on this zone and is not supervised This zone does not report restore codes If a supewised zone with restore reporting ability is desired then program one of the 6 zonas as a 24 Hr Alarm If used as a keyswitch then triggers are available for either an arming or ready status indication see programming ques...

Страница 9: ...s terminal detivers constant unregulated 10 0 15 5VDC power for devices requiring a constant power such as VS279 It is connected to a bell fuse F2 NOTE Constant power for these devices n also be obtained by splicing the RED battery lead with an in hne fuse of 3 Amps BELL OUTPUT The total output power available for sounding devices is 1 amp at 10 5 1 j 5 VDC for residential applications or 12 0 14 ...

Страница 10: ...ition of the FBII Model 117 module Consult the 117 Installation Instructions for hookup information With this device some systems can obtain dialtone where it is not available At the moment telephone line seizure occurs the Telco Tip is momenta connected to earth ground to access dial tone NOTE The 117 module has not been tested for use in UL installations 2 3 AUXILIARY DEVICE CURRENT DRAW WORKSHE...

Страница 11: ... onto the mounting clps 4 Place the washer provided over the wire jumpers located within the middle of the PC board Secure the PC board to the middle mounting clip of the enclosure through the washer using the screw provided 5 Secure the remaining sides of the PC board to the enclosure using the screws provided OFCLIPINeTALLATION REQUIREO DETAILSIOEVIEW A CABINETTAB OFCLIPANO OARD WTHOUTCLIP INSTA...

Страница 12: ... to wall through the four outer holes using suitable mounting hardware not provided 3 Connect keypad wiring to control panel and secure the keypad to the mounting ring using the four painted screws provided U SURFACE MOUNTING Using optional XL4600RMBX ti 1 Depanding on type of installation run the keypad wifing out of the rear top bottom or sides of the backbox 2 Attach backbox to wall at desired ...

Страница 13: ...keypad cutout B MOUNTING DIRECTLY TO AN ELECTRICAL JUNCTION BOX The plate cen be mounted directly to a single or double gang electrical junction box Use the screw holes provided and HOLES W for a single gang box or HOLES W for a double gang box C MOUNTING DIRECTLY TO A WALL OR OTHER SURFACE Provide a wirino hole in the mountina surface Position the plate a W RING OPENING o er the hole Ind mounting...

Страница 14: ...pad and ramove the Phillips head screw teml ondiagram intheupper left hand side of the keypad printed circuit board NOTE This screw is located immediately to the Iaft of the keypad connector 4 Attach the black metal mounting strap to the rear of the keypad as follows see diagram Face the pointed end of the mounting strap facing tha keypad front This will be usad to latch onto tha inside of the wal...

Страница 15: ...rdly ON while the system ISdisarmed NORMAL OFF 2 ARWDISARM LEO This LED indi tes whether the system is currently armed ON or disarmed OFF This LED will also btink tist to show that alarms have owurred or btink slowly upon failure to communi te with the Central Station 3 STAY LED This LED dsplays whether the system has been armed in the STAY mode or the STAY lNSTANT mode If the INSTANT LED is ON an...

Страница 16: ...essing the two keys top bottom labeled P at the same time initiatee a CS transmission if programmed of PANIC AUXILIARY or FIRE annunciates the keypad sounder and turns on the bell output If not programmed to transmit these keys can only result in a local warning as follows see question 05 location 1 Keypad Souder Steady for PANIC Pulsing for FIRE and AUXILIARY Bell Out ut Steady for PANIC Pulsing ...

Страница 17: ...rgla zones are good not faulted On LED based keypads this requires that the READY LED is on On LCD keypads the following message will appear m 1 TO ARM Enter any programmed four digit user NOTE The factory default for user l is 1234 The ARMED LED will hght and the user may exit through an exi enby zone for the time period programmed as the exit delay The system n be armed without the backup batter...

Страница 18: ... by pressing the BYPASS button followed by another zone number within a ten semnd petiod After this ten second period it will be necessay to enter the entire command including the user code After a successful bypass the keypad sounder will sound the acknowledge beep and the respective zone LED will WINK SLOWLY The bypass rules are FIRE zones cannot be bypassed 24 hour zones can be bypassed however...

Страница 19: ...ush code If no CS code is dafined in question 16 than user number 6 will be a normal user code he e ADD Or CHANGE USERS CODE USER USER USER ID CODE Press CODE button USER Enter Master User ID code user 1 USER Press Desired user to be programmed l 6 USER ID Enter Four digit user rode Valid digits are O 9 Example Define user 3 with an ID of 7493 Assume master user code is 1234 CODE 123437493 An ackn...

Страница 20: ...rmat is defined NOTE To disarm the usar code is required 7 3 TOGGLE CHIME 6 This quick command is enabled in question 05 location 4 by selecting User On fine Downloading If any zones are programmed with a chime option ace programming questions 1 O 1 5 then 6 will turn the system chime ON or OFF depending on its original state NOTE This will toggle the chime feature for the entire system Since ther...

Страница 21: ...he EZ Mate Downloader Software known as Default Lockout If selected then a system default raset will change all of the programmable options with the exception of the CSID a code usad by the software to identify the panel during ramote connections and the installer code This prevents hostile account takeovers 8 1 2 INSTALLER MODE 1 USER CODE DEFAUL The user codes can be reaat to factoy default valu...

Страница 22: ...uest while on line no additional telephone Mll is needed On line connection can be made as follows 1 Installer completes installation and attaches a handset to telco terminals tip ring or uses the standard home telephone to dial the CS Downloading modem telephone line Connection is made with a person at the CS Downloading computer and the eccount to be downloaded would be verbally identified The d...

Страница 23: ... OPENING and CLOSING signals will redirected totheseconda CS number only while all clther conditions WIII be repohed to the primay number If neither split or backup reporting is necessa then this question may be left as factory defaulted and all conditions will be routed to the Prima Telephone number only QUESTION03 CALLBACKTELEPHONENUMBER Enter the telephone number including area code and or dial...

Страница 24: ...s which are accepted by the receiver European dialing format has not been tested by UL SWINGER SHUTDOWN If selected then 3 activations of the same zone within the same arming interval will not activate the bell or the dialer This apphes only to burgla zones as well aa 24 Hr Audible zones For UL installations Swinger Shutdown must not be selected DIALING PULSE PE Specifies how this control will per...

Страница 25: ...ion is selected the bell will be activated for one second upon successful arming This option is required for UL Commercial Burglay applications QUESTION05 KEYPAD CONDITIONS D m This question contains four locations L1 L4 for various keypad definable options Question 05 LI Keypad Panic Fire and Auxiliary Defasrlt 1 Enter the digit for the desired system options from the table below in location L1 N...

Страница 26: ...Arming NOTE Stay Arming is always enabled Quastion 05 L3 Quick Commands Rasat Enable Default O Enter the dioit from the table below in Ioation L2 NOTE The checkmark highlights which options are seleded QUICK FORCED ARM Specifies whether Quick For d Arming 2 will be permitted If the system is armed by this method itwill arm the system bypasaing any faulted zones Openings Closings will report user 8...

Страница 27: ...system chime CS TEST RING BACK Normally after a CS Test Report has reached the Central Station a sounder ringback Carl be heard from the keypad indicatin a successful communication to the CS If SILENT is selected then NO sounder ringbsck 8 will be heard from the keypad a era CS Test Report If AUDIBLE is selected then s sounder ringback will be heard from the keypad after a CS Test Repofl USER 5 AR...

Страница 28: ...th F indi ting an infinite fire bell cutoff Example 3 9 minutes For UL installations the minimum fire bell cutoff time shall be 6 minutes QUESTION 07 MISCELWNEOUS SYSTEM OPTIONS There are 4 Iosations L1 L4 within this question which define various system timing options as follows Question 07 L1 Entw Delay 2 Default 2 Enter the desired entry delay time Refer to ExiffEnt Times in question 06 for val...

Страница 29: ... selected in the absence of any other signal Select from daily 24 hour weekly 27 days 60 daya or 90 days Trsnsrnission of any signal will reset the CS Test clock For example if a business opened and closed 6 days a week then a teslt signal will be generated at the intewal selected afl er the last closing signal Enter the CS Code in question 18 lo tion 1 NOTE This must be selected for UL installati...

Страница 30: ... will terminate NOTE Unlese otherwiee specified the trigger output is nornsslly flosthsg end actively sinks on activation QUESTION 08 ACCOUNT NUMBER 1 Enter the three 3 or four 4 digit subscriber account number for Central Station phone number 1 in locations LI L4 If a three 3 digit number is used then enter an A in location L4 Vafld entries are O 9 and B F The value A is interpreted as the null v...

Страница 31: ...arm interior zones are bypassed ifthe system ia armed inthe STAY MODE interior zones emp oy the Exit Error Warning feat jre described in the note below PERIMETER This zone type sometimes known as INSTANT will generate an alarm when violated while ithesystem is armed E_ EXIT ERROR WARNING At the ond of exit timea 1 second window is atsrted If any delay orinb riorz ones T are violated after arming w...

Страница 32: ...ll be reset every 4 minutes automatically in an attempt to clear the fire zone In the event the fire zone experiences an open the systam indicates fire trouble by pulsing the keypad zone LED and sounder slowly The system troubla code followed by the zone code will be reported to the CS The keypad sounder can be SILENCED through entry of ANY VALID USER CODE NOTE FIRE ZONES cannot be bypassed 24 HR ...

Страница 33: ... use foralltrsnsmissions NOTE Formore information on C SRepoting Formste refer to Appendix Aattheback ofthismanuiil 1 QUESTIONS40 15 ZONES 1 6 There are 4 Iocstions L1 L4 within each of these questions which define the operation of the zones Enter a 2 digit number in locations L1 and L2 from the zone c lart for the desired type for this zone Enter the desired alarm code in locations L3 Ind L4 for ...

Страница 34: ...stion 18 L1 Opening Code Default A Question 18 L2 Cluing Code Default A L1 is the single digit OPENING CODE L2 is the single digit CLOSING CODE Enty of AA into these two locations means that openings and closings are not desired If a dialer format other than standard is programmed then the second digit transmitted will be the user number Question 16 L3 L4 CS Test Coda Default AA L3 L4 is the CS Te...

Страница 35: ...at will b transmitted upon activation of the keypad fire condition pressing the 7 9 keys on the keypad This code can vary from any of the zones which are programmed as fire Question 20 L3 L4 Keypsd Auxiliary Ctia Dafau f AA 1 3 L4 is the code transmitted to th eCS for keypad aux condition 1 3 from the keyped NOTE These keypad emergency conditions are optional and can be enabled within question 05 ...

Страница 36: ...lt 2466 1 Press button This indi tes Installer Mode 1 41 2 WHAT YOU SEE ON THE LED KEYPAD PROGRAM MODE READY LED Upon entering the installer keypad programming mode the READY LED will slowly pulse and will mntinue to pulse until leaving this mode The remaining LEDS display the question number and lo tion wntents as indimted below E 3 y QUESTION NUMBER 4 3 1W y 06 Rdy SLOWLY PULSING 7 08 v L XL4600...

Страница 37: ...following display will appear i The display shows the current queetion number QUES tha location within the question L and the current value within that location DATA This corresponds to the programming worksheet 11 4 HOW TO ENTER DJ4TA TMs section of the manual describ ss the physical keystrokes to enter the data written on the program sheet MOVEMENT BETWEEN QUESTIONS System program mode starts wi...

Страница 38: ...E STAY BU ON TO EXIT THE SYSTEM PROGRAM MODE All the LEDS will turn ON for approximately 10 sewnds before the system returns to normal daily operation QUESTIONACKNOWLEDGMENT The keypad will heap between keystrokes In addition a beep will be generated mnfirming advancement between questions numbers Four beeps will be generated if an invatid input is entered Upon entry of invalid input you are posit...

Страница 39: ...23 to access question 23 Men programming the English zone descriptors the following techniques are used to program the characters Inse a SPACE and advances the tumor cool Moves the tumor to tb LEFT one spaa lNSTAIN MOVSS we cumorto Me RIGHToneswce m i INCREMENTS the charsster one at a time at the cursor E r PI Scrolls fomrd UP through the charscter set NOTE Pressing any key WII stop the scroll 9 D...

Страница 40: ...ystem Default or User Code Defiult through Inetsller Mode 1 refer to the Installer Modes section of this manual The Zone Descriptors will NOT return to their default valuee NOTE A programming option exists within the EZ Mate PC Downloader devices known as DEFAULT LOCKOUT If this option is selected then a system default will not overwrite the CSID or installer mde potion of the program Ttis will pr...

Страница 41: ...atid four digit user code BYPASS Enter sny vakd four digit user code Zmre BYPASS Zone CODE Enter master user cede user fl Enter 4 tigit user codel CODE Enter master user code user fl r M 11 w 21 w 61 m 91 r mat the same time 9 at the same time 1 3 st the came time Enter user code 6 CODE Enter insblier code 1 CODE r Enter installer code 2 CODE Enter installer code 3 CODE fl Enter installer code 4 C...

Страница 42: ...ing 8 times for each CS Telephone number programmed a Hssoff is not received the system will display Communication Failure at the keypad This message is cleared after the neX succsasful transmission or by the user at the keypad The following iss general description of the various formats transmitted by this system 4 f STANDARD 3X1 Or 4X1 The Standard Repotiing Fornrat AAA E or AAAA E where AAAA Th...

Страница 43: ...code digits The Partial Extended format is a connbinationof both the Standard and Extended formats It transmits in Pulsf a standard message for alarm conditions and an extended message for restores and other system conditions To rapoti a standard message enter a numerical digit O 9 in the first of the 2 digit repoting code for an extended message enter a tlexadecimal digilt B F in the first of the...

Страница 44: ...ansformer connection battery connectio check A C input volt batt volt w transformer discormected check auxiliary fise lb Check term 15 12 for 12VDC 2a Check transformer connection check A C input volt 2b Replace keypad 3a Check battery cormectiou check batt volt w transformer disconnected check battery fuse 3b Same as 3a except volt 1lVDC otherwise let battery charge replace battery 4a Telephone l...

Страница 45: ...XL 2S SYSTEM PMNNING WORKSHEET Ni Address Instiaflerimeter 24 HourAlam Dela 24 HourTrouble Nomal User Nomal User Nomal User nly YCI N h YCINO 1 chmse or deleteotheruser codes ...

Страница 46: ...PAD CONDITIONS 06 SYSTEM TIMEOUTS 07 MlSCEL SYS OPTIONS 08 ACCOUNT 1 09 ACCOUNT 2 p j l 10 ZONE 1 TYPE CS CODE 11 ZONE 2 wPE CS CODE 12 ZONE 3 TYPE CS CODE 43 ZONE 4 TYPE CS CODE 14 ZONE 5 NPE CS CODE m l 15 ZONE 6 TYPE CS CODE m IM II 6 AMBUSH AC LOSS wa p J7 PANIC LOW BA ERY 18 OPEN CLOSE CS TEST 20 KHPAD FIRE AUX 4x 4 Im a 00 INSTALLER CODE I uaisl lwul ...

Страница 47: ...Motion Det ors cen only deteti intrusion wittin the designed ranges as diagramed in their installation manual Passive Infrared Datecfors dc not provide volumetric area protection They do create multiple beams of protection and intrusion n only be detected in unobstructed areaa covered by the beams They cannot deteti motion or intrusion that takes place behind walls ceilings floors closed doors gla...

Страница 48: ...s warranties and ia the only warranty made by seller on this product No increase or alteration written or verbal on the obligations of this Lmited Warranty is authorized FEDEWL COMMUNICATIONS COMMISSION FCC STATEMEN Thisequipmenthasbeen testedto FCC requirementsandhas beenfounda ptable foruse The FCC requiresthe followingstatement for your information This equipment generates and uses radio freque...