175
F80W
DIAGRAMS
3.7.6 List of error codes displayed on the display
Code F
Short description
Causes and troubleshooting
F01
hydraulic oil sensor
short circuit to the ground detected – check the connection (X41, RD 141, WH 227)
F02
material feed sensor
short circuit to the ground detected – check the connection (X43, RD 143, WH 229)
F03
F03 brake pressure sensor
short circuit to the ground detected – check the connection (X42, RD 142, WH 228)
F04
engine cooling sensor
“short circuit on the battery detected – check the connection (X18:5, X35)”
F05
engine oil level sensor
“short circuit on the battery detected – check the connection (X17:4)”
F06
engine air filter sensor
“short circuit on the battery detected – check the connection (X18:3)”
F07
drive pump sensor
"short circuit to the ground or on the battery detected or no connection – check
the connection (X38, WH 214, WH 217, WH 222)"
F11
controller
“the most frequent cause: the controller is not calibrated; - parameter error 1 through
6: redundancy fault; - parameter error 7: not calibrated; - parameter error 8: error in
the main channel; - parameter error 9: error in the redundant channel (X36)”
F12
speed potentiometer
“the most frequent cause: an error in the main channel; - parameter error 1 through
6: redundancy fault; - parameter error 8: error in the main channel; - parameter er-
ror 9: error in the redundant channel (X37)”
F13
travel mode switch
short circuit to the ground detected – check the connection (X53, RD 153, WH 243)
F14
material feed mode switch
short circuit to the ground detected – check the connection (X52, RD 152, WH 242)
F15
material feed direction switch
short circuit to the ground detected – check the connection (X51, RD 151, WH 240,
WH 241)
F16
screed height switch
short circuit to the ground detected – check the connection (X48, RD 148, WH 236,
WH 237)
F19
screed vibration switch
short circuit to the ground detected – check the connection (X49, RD 149, WH 238)
F21
horn button
short circuit to the ground detected – check the connection (X45, RD 145, WH 231)
F22
engine start switch
short circuit to the ground detected – check the connection (137)
F23
safety button
short circuit to the ground detected – check the connection (X44, RD 144, WH 230)
F24
screed extension switch – left, inside short circuit to the ground detected – check the connection (X46, RD 146, WH 233)
F25
screed extension switch – left,
outside
short circuit to the ground detected – check the connection (X46, RD 146, WH 232)
F26
screed extension switch – right,
inside
short circuit to the ground detected – check the connection (X47, RD 147, WH 234)
F27
screed extension switch – right,
outside
short circuit to the ground detected – check the connection (X47, RD 147, WH 235)
F28
forward control switch
short circuit to the ground detected – check the connection (X36)
F29
rearward control switch
short circuit to the ground detected – check the connection (X36)
F30
control neutral position switch
short circuit to the ground detected – check the connection (X36)
F31
travel pump – forward
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X65, Y12, WH 263, WH 265, WH 266)"
F32
travel pump - rearward
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X66, Y13, WH 264, WH 266)"
F33
drive pump safety
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X65, X66, Y12, Y13, WH 263, WH 264, WH 265, WH
266)"
F34
brake release output
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X60, Y7, WH 256, WH 257)"
F35
brake release safety
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X60, Y7, WH 256, WH 257)"
F36
material feed forward valve
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X54, Y1, WH 244, WH 246, WH 247)"
F37
material feed rearward valve
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X55, Y2, WH 245, WH 247)"
F38
material feed safety
"short circuit to the ground or on the battery detected or no connection – check
the connection and the coil (X54, X55, Y1, Y2, WH 244, WH 245, WH 246, WH 247)"
Содержание Dynapac F80W
Страница 1: ...OPERATING MANUAL Asphalt paver wheeled F80W Hatz 4812217930 ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 14: ...8 F80W ...
Страница 15: ...9 F80W SPECIFICATION MANUAL 1 SPECIFICATION MANUAL F80W Hatz Tier 4 Final ...
Страница 18: ...12 F80W W1 W2 W W3 W4 B L L1 H H1 D451170A A L2 1 2 Dimensional drawing of the machine ...
Страница 23: ...17 F80W D451175 α 12 21 SPECIFICATION MANUAL Lateral static stability with an empty and full hopper ...
Страница 32: ...26 F80W Notes ...
Страница 33: ...27 F80W SPECIFICATION MANUAL Notes ...
Страница 34: ...28 F80W ...
Страница 35: ...29 F80W OPERATING MANUAL 2 OPERATING MANUAL F80W Hatz Tier 4 Final ...
Страница 62: ...56 F80W ...
Страница 79: ...73 F80W 451043 451044 D451042 OPERATING MANUAL Augers Screed Conveyor ...
Страница 123: ...117 F80W OPERATING MANUAL Notes ...
Страница 124: ...118 F80W ...
Страница 125: ...119 F80W MAINTENANCE MANUAL 3 MAINTENANCE MANUAL F80W Hatz Tier 4 Final ...
Страница 126: ...120 F80W ...
Страница 191: ...185 F80W 451190 MAINTENANCE MANUAL ...
Страница 193: ...187 F80W 451900 1 1 1 11 5 A 12 V 2 2 10 12 3 3 3 4 5 4 6 7 8 9 8 MAINTENANCE MANUAL ...
Страница 196: ...190 F80W 3 8 Appendices Notes ...
Страница 197: ......
Страница 198: ...www dynapac com ...