5.4 Checking the fuel level; topping up fuel
DANGER!
Danger to life caused by explosive gas-air
mixes!
–
Do not allow gasoline to come into contact with
hot components.
–
Smoking and open fire is prohibited.
–
Keep away from heat sources, sparks and
other sources of ignition.
–
Do not spill any gasoline.
NOTICE!
Danger of engine damage!
–
Monitor the entire refuelling process.
–
Contaminated fuel can cause malfunction or
even damage of the engine. If necessary, fill in
fuel through a screen filter.
–
Use only fuel of the permitted specification
Chapter 8.2.2 ‘Fuel’ on page 71
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Park the machine safely
Chapter 6.5 ‘Parking the machine
in secured condition’ on page 62
2.
Clean the area around the filling port.
3.
Remove the cap and check the filling level visually.
4.
If necessary, fill in fuel through a funnel with screen filter.
5.
Close the cap.
B-SYM-1069
Fig. 30
Fig. 31
Checks prior to start up – Checking the fuel level; topping up fuel
DFP8
49
Содержание DYNAPAC DFP8
Страница 6: ...Table of contents DFP8 6...
Страница 7: ...1 Introduction Introduction DFP8 7...
Страница 11: ...2 Technical data Technical data DFP8 11...
Страница 15: ...3 Concerning your safety Concerning your safety DFP8 15...
Страница 39: ...4 Indicators and control elements Indicators and control elements DFP8 39...
Страница 45: ...5 Checks prior to start up Checks prior to start up DFP8 45...
Страница 52: ...Checks prior to start up Checking the water level topping up DFP8 52...
Страница 53: ...6 Operation Operation DFP8 53...
Страница 64: ...Operation Parking the machine in secured condition DFP8 64...
Страница 65: ...7 Loading transporting the machine Loading transporting the machine DFP8 65...
Страница 69: ...8 Maintenance Maintenance DFP8 69...
Страница 100: ...Maintenance As required DFP8 100...
Страница 101: ...9 Troubleshooting Troubleshooting DFP8 101...
Страница 107: ...10 Disposal Disposal DFP8 107...
Страница 109: ......
Страница 110: ......