4.7 Proximity switches, B08 and B38
B08 Proximity switch for travel lever “0” position
B38 Proximity switch for vibration lock
The working principle is based on the principle of the dampened
LC-oscillator. The coil of the oscillation circuit forms a high-fre-
quency magnetic stray field.
This stray field leaks out from the active area of the proximity
switch. If metal or non-ferrous metal enters into the response
range, energy is absorbed. The oscillator is thus dampened and
the resulting change in current consumption is evaluated.
Fig. 76: Proximity switches on travel
lever
Working principle