4.
Check condition and tension of V-belt.
ð
Compression measurement:
5 - 15 mm (0.2 - 0.6 in).
5.
The V-belt cannot be re-tightened.
Replace the V-belt if it is damaged or if the compression
measurement is exceeded
Chapter 8.8.5 ‘Replacing the V-
.
6.
Fasten the V-belt guard (1).
8.10.5
Checking the oil level in the exciter housing
NOTICE!
Components may get damaged!
–
Use only oil of the permitted specification
Chapter 8.3 ‘List of fuels and lubricants’
.
Protective equipment:
n
Working clothes
n
Safety shoes
n
Protective gloves
1.
Drive the machine onto horizontal, level, firm ground.
2.
Park the machine safely
Chapter 6.5 ‘Parking the machine
in secured condition’ on page 61
3.
Allow the machine to cool down.
B-GEN-0122
Fig. 139
1
B-692-0151
Fig. 140
Maintenance – As required
DRP15X
104
Содержание DYNAPAC DRP15X
Страница 6: ...Table of contents DRP15X 6 ...
Страница 7: ...1 Introduction Introduction DRP15X 7 ...
Страница 11: ...2 Technical data Technical data DRP15X 11 ...
Страница 15: ...3 Concerning your safety Concerning your safety DRP15X 15 ...
Страница 39: ...4 Indicators and control elements Indicators and control elements DRP15X 39 ...
Страница 45: ...5 Checks prior to start up Checks prior to start up DRP15X 45 ...
Страница 53: ...6 Operation Operation DRP15X 53 ...
Страница 62: ...Operation Parking the machine in secured condition DRP15X 62 ...
Страница 63: ...7 Loading transporting the machine Loading transporting the machine DRP15X 63 ...
Страница 68: ...Loading transporting the machine Transport wheels DRP15X 68 ...
Страница 69: ...8 Maintenance Maintenance DRP15X 69 ...
Страница 109: ...9 Troubleshooting Troubleshooting DRP15X 109 ...
Страница 116: ...Troubleshooting What to do if the engine has flooded DRP15X 116 ...
Страница 117: ...10 Disposal Disposal DRP15X 117 ...
Страница 119: ......
Страница 120: ......