48
5 Operation
5.1 Commissioning
Before starting up the servomotor together with a mechanism, the following points must be
checked:
The motor has been installed according to the specifications.
The ribbon cable of the motor is connected according to the requirements (risk of polarity rever-
sal!) and is laid so that it cannot be damaged during operation. The maximum load values must
be noted and observed. See
Chapter 1.4 “Ambient conditions”
.
Lengthening the connection leads can affect the function and properties with respect to EMC. All
connection leads may not exceed a length of 3 m.
The connected mechanism is installed free of blockages.
The loads and stresses on the shaft (axial, radial and torques) are within the specified values.
CAUTION!
Risk of injuries
A risk of injuries can result from protruding rotating or moving parts of the driven mechanism.
f
Cover rotating and moving parts with appropriate devices.
CAUTION!
Risk of burns
Depending on the load and ambient temperature, very high temperatures can occur on the surface
of the unit.
f
Contact protection (guards) must be provided if necessary.