For calculating the avg. values, the CCS uses two different algorithms depending on whether
a flow signal is connected or not.
If a flow signal (analog or pulsed) is connected to the system, the avg. contamination is
weighted with the current flow rate. For an exact result of the average contamination, a flow
meter is required.
If no flow signal is connected, the avg. value is the arithmetic medium of the contamination
during the refuelling process.
If a USB drive is plugged and a history file is available, you can download it by a click on
Download. Make sure your browser allows pop-ups and supports File Transfer Protocol.
You can download the history also by entering the URL
ftp://192.168.10.231/c/history
3.2.6.4 Logfiles
Since firmware 2020-10-28 you can comfortably download logfiles via web browser. You
don’t need to unplug the USB drive anymore.
Click Logfiles. If your browser allows pop-ups and supports FTP it shows all logfiles saved on
the USB drive.
You can click each file to download / open it.
For a more comfortable file management of logfiles, we recommend Windows Explorer or
another tool like FileZilla. Enter the path
ftp://192.168.10.231/c/logging/
programs to download logfiles.
3.2.6.5 Info screen
When pressing the Info button on the main screen
– all relevant contact info’s are displayed
on this screen