3. Preparation
SD3 Series Instruction Manual
Preparation
2. System Wiring
2. System Wiring
2. System Wiring
DANGER
Be mindful when wiring and handling high voltage materials
To comply with the EC Directive, select appropriate devices, each of which is
compliant with its applicable standards.
FG connection is a must.
Connect the input power of control power to the same power supply that the
primary circuit power is connected to.
Do not use the electromagnetic contactor (installed on the primary circuit power
side) to run or stop the motor.
Do not install a switch between the control power supply and the amplifier. Install
the switch on the primary input side of the control power supply.
For high-voltage cables, use wires of 600 V withstand voltage or more.
For a CN1 connector cable, use a shielded twisted-pair cable of 2 m or less.
The encoder cable length must be 20 meters or less.
For stranded wire, use insulation coating, rod or ring crimp terminals.