CPC309 Intel Atom D510-based SBC
Specification
Table 3-5: Purpose of Audio connector contacts
When manufacturing cable adapters for connection to XP19 and XP20 it is recommended to
use the sockets of PHR-5 (JST) / PHR-2 (JST) type, accordingly designed for wire crimp with
SPH-002T-P0.5S (JST) contacts, or ACS00031-01 and ACS00031-03 accessories (see Table
1-3).
3.4.4 Serial interfaces
The module has two serial ports: COM1
– COM2.
3.4.4.1 COM1 and COM2 ports
COM1 and COM2 ports are operating in the full (9-wire) RS 232 interface mode and have basic
addresses (see Table 3-16) and interrupts (see Table 3-17) standard for PC/AT. COM1 port can
be used for console input/output. For the connection with a remote console (PC in the terminal
simulation mode with parameters of data exchange for COM port: 115200 bps, 8, N, 1) it is
necessary to use connection via the null-modem cable
1)
and ACS00023-04 cable from the
module delivery checklist to the connector of COM1 (XP3) port of the module. See subsection
1.2.2 Delivery checklist.
Attention!
When “Hyperteminal” program is used as a terminal, for proper presentation it is required to
remove tick from the setting “Wrap lines that exceeded terminal width” in the ASCII program
parameters settings.
Rate of exchange for COM1 and COM2 ports do not exceed
– 115,2 Kb/s. Ports are software
compatible with UART 16550 version.
COM1 and COM2 ports are routed to XP3 and XP6 connectors of IDC10 type, accordingly
(with a pith of 2 mm). Information on the purpose of XP3, XP6 connector contacts for the
connection to COM1, COM2 ports is given in Table 3-6.
1)
Standard cable is not included into the delivery checklist and additional accessories of the module, to be
purchased separately.