background image

Содержание G346 BH Series

Страница 1: ......

Страница 2: ...proprietary pressure assisted gripping and sealing technology that increases gripping pressure as the pressure increases virtually eliminating accidental removal under pressure A floating split colle...

Страница 3: ...tion is sought z z Connectors may only be dismantled by FasTest or trained personnel z z Do not use excessive force when connecting See Operating Instructions outlined in this manual z z Filling gas c...

Страница 4: ...Tighten to a max torque of 15 ft lbs A higher torque can result in damage causing leaks when the system is pressurized Ensure that the connectors cannot be damaged when loading and removing the cylind...

Страница 5: ...connection is made correctly it will connect with relative ease Ensure that the actuating loop has traveled to a position below parallel to the connector body Check to make sure the collets are fully...

Страница 6: ...w the pin is extended Figure 6a Demonstrates good connection to CGA 346 or CGA 540 Figure 6b Use minimal force on bail Figure 7a Demonstrates good connection to CGA 580 or CGA 590 Figure 7b Use minima...

Страница 7: ...NOT ATTEMPT TO DISCONNECT ACTUATOR STYLE CONNECTORS WHILE UNDER SYSTEM PRESSURE See Safety Pin care in Maintenance section of this manual Operation Figure 9 Safety pin extends to stop sleeve travel a...

Страница 8: ...eturns for inspection as well as required maintenance costs Minimize the use of soap solutions sprayed directly onto connector These types of solutions cause a build up that can hamper proper connecto...

Страница 9: ...actuator handle will flip back easily when the connector is depressurized and the safety pin retracts Failure to wait may cause damage to the safety pin If the safety pin does not function properly t...

Страница 10: ...age to the groove Clean groove if required and insert new O ring Inspect for correct function Does the safety pin properly protrude and lock the connector under pressure Does the safety pin move backw...

Страница 11: ...field service Please contact FasTest Inc for additional information Connectors Part Numbers Material Description G346 BH SG346 SG346E Viton EPDM Replacement main seals Replacement main seals G540 BRP...

Страница 12: ...r body a Damaged or bent pin b Lack of lubrication and or dirt contamination a Field replacement of actuator pin assembly b Remove safety pin assembly clean and lubricate with approved lubricant Safet...

Страница 13: ...Replace cylinder valve Damage deformation or distortion to connector body sleeve and collet threads Possible internal leakage Visual inspection of connector Difficult operation of connector Improper o...

Страница 14: ...FasTest Inc 1646 Terrace Drive Roseville MN 55113 Support 800 444 2373 Fax 651 645 7390 www fastestinc com 12 Bail Handle Compressed Gas Connectors notes...

Страница 15: ...Bail Handle Compressed Gas Connectors FasTest Inc 1646 Terrace Drive Roseville MN 55113 Support 800 444 2373 Fax 651 645 7390 www fastestinc com 13 notes...

Страница 16: ...be returned prepaid transportation to FasTest Inc together with information describing the product s performance unless disposition in the field is authorized in writing by FasTest Inc WARNING High p...