*7(.$8720$7,21'LPHQVLRQ'ULYH6XLWH/DNH)RUHVW&$3KRQHZZZJWHNDXWRPDWLRQFRP
7
FI Series User Manual
8.1. Follow steps 7.1 through 7.3.
8.2. Take care when removing the housing (G)
because the actuator assembly and spring
can come out. See Figure 10.
8.3. Replace the actuator assembly and spring as
shown.
8.4. Follow steps 7.5 through 7.7.
Actuator Assembly
8. Replacing Internal Seals on a Connector with Sure Seal™
Figure 11.
Actuator Assembly
SURE SEAL™
7. Replacing Internal Seals on a Standard Connector
7.1. Remove retaining ring, main seal set, and spacer.
7.2. Slide the housing forward until the stroke limiter (F) is engaged.
7.3. Use a small pick to remove the snap/retaining ring. See Figure 8.
Note: if repairing a connector with Sure Seal™, refer to step 8 below.
7.4. Fully remove the housing (G) from the piston (H). See Figure 8.
7.5. Use a small pick to remove the internal (L) o-rings. See Figure 9.
7.6. Lubricate the new o-rings with petroleum jelly and re-install.
7.7. Re-install housing, stroke limiter, spacer, main seal set, and retaining ring.
Figure 9.
Removal of Stroke Limiter
(F) Stroke Limiter
(L) O-Rings
Figure 10.
Removal of Internal O-Rings
(G) Housing
(H) Piston