![Fastech Ezi-STEPII EtherCAT MINI Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/fastech/ezi-stepii-ethercat-mini/ezi-stepii-ethercat-mini_user-manual_546254036.webp)
4. CiA402 Drive Profile
4.2
Error Code
Once Error generates at Controller (Sense Fault signal), changed to ‘Fault reaction active’ status.
Under ‘Fault’ / ‘Fault reaction active’ status, types of error can be checked by Error code (603Fh).
Error code
History
1
Status
Description
Hex / Dec
7500h / 29952
500
EtherCAT Communication
Error
An error occurred in EtherCAT Communication.
FF01h / 65281
1
Over Current Error
The current through power devices in inverter
exceeds 4.8A.
FF02h / 65282
2
Over Speed Error
Motor speed exceed 3,000 [rpm].
FF05h / 65285
5
Over Temperature Error
Inside temperature of drive exceeds 85°C.
FF06h / 65286
6
Over Regenerated
Voltage Error
Motor Back-EMF is higher than 48V.
FF07h / 65287
7
Motor Connection Error
Abnormal connection between drive and motor.
FF0Ch / 65292
12
ROM Error
Error occurs in parameter storage device.
(ROM)
FF31h / 65329
49
Drive Alarm
Generated Extra alarms generated from drive.
FF32h / 65330
50
Internal communication
error of drive
Communication error from internal components
of drive generated. (Time-out)
FF34h / 65332
52
Internal communication
error of drive
Communication error from internal components
of drive generated. (CRC Failed)
FF35h / 65333
53
Internal communication
error of drive
Communication error from internal components
of drive generated. (Command Failed)
FF3Ch / 65340
60
Torque enable Failure
The SVON signal of drive was not on during the
Torque Enable process.
FF3Eh / 65342
62
TQOFF Input Error
Torque Enable command was called while the
Safety function was active.
FF3Fh / 65343
63
Drive SVOFF Detect
Drive is torque disabled by itself.
FF42h / 65346
66
Torque disable Failure
The SVON signal of drive was not off during
the Torque Enable process.
FF44h / 65348
68
Over Speed in CSP
In CSP mode, the commanded speed value exceeds
the speed limit and cannot be followed.
FF45h / 65349
69
Safety Activated
The safety function is activated and drive is
Torque Disabled.
FF47h / 65351
71
Network Initialization
Error
An error occurred while initializing the
hardware of EtherCAT communication.
FF49h / 65353
73
Synchronization Type
Error
CSP mode was used in the wrong EtherCAT
synchronization type. CSP mode is available
when EtherCAT synchronization type is DC Sync
Event.
FF4Bh / 65355
75
Abnormal Safety Input
State
2
The Digital Inputs allocated to TQOFF Input
are different from each other.
FF4Ch / 65356
76
Internal communication
failure of drive
Failure to start Communication of internal
components of drive.
FF64h / 65380
100
ROM Initialization
Error
ROM is blank status.
FF65h / 65381
101
ROM Initialization
Error
Check sum of ROM is not matched.
FF66h / 65382
102
FRAM Access Error
Error generated during FRAM accessing.
FF6Eh / 65390
110
ROM Reading Error
Error generated during ROM reading.
FF79h / 65401
121
ROM Writing Error
Error generated during ROM writing.
FF7Ah / 65402
122
ROM Writing Error
Error generated during ROM writing.
FF7Bh / 65403
123
ROM Writing Error
Error generated during ROM writing.
FF7Ch / 65404
124
ROM Writing Error
Error generated during ROM writing.
FFC8h / 65480
200
ROM Data Out of Range
Error
Some parameter values stored in ROM are out of
range.
1
The value displayed in the Object 2021h: Error code history.
2
The ’Abnormal Safety Input State’ alarm can be clear by recycling the power of the controller. It can not clear by ’Fault Reset’
command of Control word.
Rev.37
FASTECH Co., Ltd.
36
Содержание Ezi-STEPII EtherCAT MINI
Страница 1: ...Open Loop Stepping System EtherCAT Network User Manual Ezi STEPII EtherCAT MINI FASTECH Co Ltd ...
Страница 10: ...Chapter 1 Product Specification Rev 37 FASTECH Co Ltd 10 ...
Страница 14: ...Chapter 2 Installation Rev 37 FASTECH Co Ltd 14 ...
Страница 25: ...Chapter 3 EtherCAT Communication Rev 37 FASTECH Co Ltd 25 ...
Страница 31: ...Chapter 4 CiA402 Drive Profile Rev 37 FASTECH Co Ltd 31 ...
Страница 55: ...Chapter 5 Operation Rev 37 FASTECH Co Ltd 55 ...
Страница 59: ...Chapter 6 EtherCAT Object Dictionary Rev 37 FASTECH Co Ltd 59 ...