www.fastech.co.kr
49
Communication function
Communication function
9.
1)
It has embedded 2 Port Ethernet switching Hub for daisy-chain connection.
2)
Use TCP and UDP protocol.
3)
In case of using TCP, drive can be connected at the same time from GUI (Graphical User
Interface) and application program (user program).
4)
4) In case of using UDP, you can connect and use the drive at the same time from GUI
(Graphical User Interface) and one or more application programs (user programs). However,
If you connect more than 2 applications, communication delay may occur.
5)
Please refer to
「5.2 System Configuration」
for PC connection example
6)
The signal contents of the RJ45 connector of the drive are as follows.
(Same as general Ethernet 10/100 Base-T)
RJ45 Pin No.
Function
1
TD+
2
TD
3
-
4
-
5
RD+
6
RD-
7
-
8
-
case
Frame GND
7) Basic IP Address : 192.168.0.xxx
Basic Gateway : 192.168.0.1
Basic Subnet Mask : 255.255.255.0
Содержание Ezi-Step II Plus-E
Страница 1: ... Rev 03 User Manual Text ...
Страница 8: ...www fastech co kr Specifications of the Drive 8 ...
Страница 11: ...www fastech co kr 11 Specifications size of the Motor Motor Size 3 2 ...
Страница 12: ...www fastech co kr Specifications size of the Motor 12 ...
Страница 16: ...www fastech co kr Configuration 16 Controller configuration 4 2 1 General Drive For 20 60 mm motor ...
Страница 17: ...www fastech co kr 17 Configuration 2 86 mm motor drive ...
Страница 18: ...www fastech co kr Configuration 18 External Wiring Diagram 4 3 1 General Drive For 20 60 mm motor ...
Страница 19: ...www fastech co kr 19 Configuration 2 86 mm Motor Drive ...
Страница 67: ...www fastech co kr 67 Appendix Brake Installed Motor Specification and Size 12 3 ...