www.fastech.co.kr
55
Protection Function
11.Protection Function
11-1.Type of Alarm
1)
If an alarm occurs during drive operation, the red LED of the status display LED flashes
and the LED flashes like the alarm number and the protection function as shown in the
following table is activated.
2)
If the alarm number is higher than 15, the alarm LED does not flash.
*1
Detection current : 4.8A
Alarm
No.
Alarm Name
Description
1
Overcurrent
The current through power devices in inverter exceeds the
limit value
*1
2
Overspeed
Command speed for motor exceeds 3,300[rpm].
5
Overheat
The internal temperature of the drive exceeds 85℃.
6
Over
regenerative
voltage
Back-EMF exceeds 48V.
7
Motor connection
The connection of drive and motor is defective.
12
ROM error
Error is occurred in parameter saving device(ROM).
50
Internal
communication
A communication error has occurred between parts in the
drive.
51
STEP ON failure
If the STEP ON command fails
60
201
IP setting error
In case of IP and Gateway set value is same
202
IP conflict
If there are any product that has the same IP address existing
on the connected network.
(Including other products)
Содержание Ezi-Step II Plus-E MINI
Страница 1: ...Rev 02 User Manual Text...
Страница 8: ...www fastech co kr Specifications of the Drive 8 Dimensions...
Страница 11: ...www fastech co kr 11 Specifications Size of the Motor Motor Size...
Страница 12: ...www fastech co kr Specifications Size of the Motor 12...
Страница 16: ...www fastech co kr Configuration 16 Controller Configuration...
Страница 17: ...www fastech co kr 17 Configuration External Wiring Diagram...
Страница 61: ...www fastech co kr 61 Appendix Brake Installed Motor Specifications and Size...