-77-
8.6 Setting the acceleration time and deceleration time
The acceleration time and deceleration time can be set so that an impact is not applied to a load
when the motor is started or stopped.
•
Setting the acceleration time and deceleration time
Setting range : 0.0 ~ 15.0 sec ( Factory setting : 0.5 sec)
-
Setting to the parameter
The acceleration time and deceleration time can be set in the parameter in normal operation
without operation data.
-
Setting to the operation data
If you want to set the acceleration time and deceleration time of each data in data mode, you
can set it in data mode.
•
Setting of deceleration time “0 sec”
If you set the deceleration time to a smaller value than the rotation speed and load, “AL.Ov”
alarm will be generated. But if the deceleration time is set to 0 seconds, it will not be decelerated
but will stop in the “E.BRAKE” status without generating an alarm.
Rotation speed
Acceleration time
Deceleration time
Time
Содержание Ezi-SPEED ESD-120-C
Страница 1: ......
Страница 9: ...9 2 Characteristics 2 1 Part number...
Страница 15: ...15 3 2 Dimensions 30W 60W 120W Drive 200W 400W Drive...
Страница 18: ...18 ESM 90 H 120 ESM 104 H 200 ESM 104 H 400...
Страница 19: ...19 4 3 Characteristics of motor torque 30W 60W 120W...
Страница 20: ...20 200W 400W...
Страница 63: ...63 8 2 Setting and 7 segments display 1 Monitor mode...
Страница 64: ...64 2 Input Output setting mode...
Страница 65: ...65 3 Parameter setting mode 1page...
Страница 66: ...66 3 Parameter setting mode 2page...
Страница 67: ...67 3 Parameter setting mode 3page...
Страница 68: ...68 3 Parameter setting mode 4page...
Страница 69: ...69 4 NVM saving mode...