-49-
•
Ground connection of drive
The drive has two ground terminals. Ground one of terminals to near drive. You can connect any
ground terminal. The ground termina without ground is reserved terminal.
Connect the motor to
ground or use the motor as required. Do not use the ground wire as a welder or a power unit.
•
Ground connection of motor
Ground terminal
- Use crimp style terminal : Ring crimp style terminal with insulation
- Teminal screw size : M4
Motor ground connection
200W, 400W motor can ground directly on the motor.
7.3.4 Connecting the I/O signals
I/O signal connects to CN4.
•
Connecting the lead wire
- Lead wire size : AWG26 ~ 20
(0.14 ~ 0.5 𝑚𝑚
2
)
- Length of lead wire stripping : 8mm
- Connect with crimp style terminal
Direct ground
connect to the motor
Ground one of
terminals to drive
Ground one of
terminals to drive
Drive of 30W, 60W, 120W
Drive of 200W, 400W