8. Acoustic leakage detection
The acoustic leakage detection menu is called by tapping on this symbol.
The following parameters can be set as per a uniform operating scheme in any of the two operating
measurement modes available for acoustic leakage detection irrespective of the actually set
measurement mode.
[1] Adjusting the sensitivity of the sensor
[2] Selecting the filter setting
[3] Adjusting the volume (headphones)
[4] Selecting the sensors (filter pre-selections)
[5[ Selecting the measurement mode
[6] Saving a measurement
[7] Uplopading a measurement
8.1
Setting the acoustic parameters
8.1.1
Adjusting the sensitivity of the sensors
If you wish to adjust the sensitivity of the microphone connected to the measurement device, please navigate
in the measurement indication window to the symbol for sensor sensitivity setting (1). Activate the symbol
and confirm your selection. The window where the sensitivity of the sensor can be adjusted will open up,
and a scale ranging from 0 to 100% will be displayed where the currently set amplification of your