![Fasel Elektronik FCU6x00 Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/fasel-elektronik/fcu6x00-series/fcu6x00-series_installation-and-operating-manual_3542243031.webp)
Settings
Installation and Operating Manual / Version V 1.02
31
NOTE!
For quick processing, have the data of the type plate such as the type, se-
ries number, variant etc. ready before making the call.
11
Settings
11.1 Adjusting range: sauna
min.
max.
Temperature
10°C
110°C
Operating time
00:15 h
06:00 (20:00*)
11.2 Adjusting range: Sauna with humidity
min.
max.
Temperature
10°C
65°C
Humidity
30% (01 F)
80% (09 F)
Operating time
00:15 h
06:00 (20:00*)
Drying temperature
80°C
110°C
Drying time
0
59 min.
Humidity
– temp., sum
according to VDE characteristic EN 60335
– 2 – 53:2003 + A1:2007 image
101
11.3 Adjusting range: Infrared
min.
max.
Temperature
40°C
90°C (45°C **)
Base temperature
--
65°C (40°C **)
Operating time
00:15 h
06:00 (20:00*)
* The control units are delivered with a maximum adjustable heating period of 6 hours.
Please contact the installer or the dealer of your sauna system if you require a heating
period of more than 6 hours.
** The temperature can be restricted to 45 °C for Austria.