Faults 

 

 

Installation and Operating Manual / Version V 1.02 

27 

 

8.2 

Messages and instructions on the display 

Messages and instructions may be shown on the display that require the operator to 
take action. 

Messag-
es/Instruction

Possible causes 

Measures 

To be carried 
out by 

Device not re-

sponding 

Sauna control unit is 
switched off. 

Switch on the sauna control unit. 

Operator 

Connection to 

the server 

failed 

1. No server connection 
with the App. 
2. No server connection of 
the Connect Box. 

1. Check the Internet connection on 
your Smartphone/Tablet 
2. Restart the Connect Box and wait for 
about 5 minutes until the connection to 
the server is established. 
Pay attention to the beep confirmation. 

Operator 

USB  

NOT EXISTS 

USB connection interrupted  Check if the USB cable between FCU 

and Connect Box is plugged in.  
Restart the Connect Box and wait for 
about 5 minutes until the connection to 
the server is established. 
Pay attention to the beep confirmation. 

Operator 

Water  

deficiency 

 

Evaporator without water 

Fill water according to the operating 
manual of the evaporator. 

Operator 

Check water inlet / magnetic valve on 
the evaporator. 

Specialist/ 
electrician 

Drying function 
interrupted 

 

After completion of the 
“Sauna with humidity” bath 
mode, the cabin is auto-
matically dried for a defined 
period and at a defined 
temperature. This drying 
function helps to avoid 
damage to the cabin, e.g. 
mould growth. This drying 
function was interrupted 
prematurely. 

Follow the instructions on the display: 
 

 Restart the drying function 

 Cancel the drying function 

Operator 

Table 8: Messages and instructions 

 

8.3 

Acknowledge message 

1.  Eliminate the cause of the error.  

2. 

 -Press the key for approx. 2 seconds. Message disappears. 

 

8.4 

Error messages  

This section describes possible faults and troubleshooting measures. 

Contact the installer or dealer for your sauna system in the event of faults that cannot 
be dealt with based on the following descriptions. Refer to the invoice, delivery note or 
the back of this manual for the address. 

Содержание FCU6x00 Series

Страница 1: ...an be combined with the following sauna control units in the FCU series Series FCU3000 FCU3200 FCU3400 Series FCU4000 FCU4200 FCU4400 Series FCU5000 FCU5200 FCU5400 Series FCU6000 FCU6200 FCU6400 Doc...

Страница 2: ......

Страница 3: ...3 Interface converter 13 3 1 4 USB cable 13 3 2 Connection and initial operation 13 3 3 Initial set up with LAN operation 13 3 4 Initial set up with WLAN operation 14 3 5 Switching off or restarting t...

Страница 4: ...n the display 27 8 3 Acknowledge message 27 8 4 Error messages 27 8 5 Acknowledge error message 29 9 Decommissioning and disposal 29 10 General 29 10 1 Limitation on liability 29 10 2 Copyright protec...

Страница 5: ...order to avoid any accidents personal injuries and damage to property DANGER shows an imminently hazardous situation that can result in severe injuries or even death if not avoided WARNING shows a pot...

Страница 6: ...is not affected by cold air flowing in from the outside 1 3 Intended use The FASEL sauna control units in the FCUxx00 series are designed exclusively for op eration and control of sauna cabins saunas...

Страница 7: ...Adherence to all the safety and operating instructions specified in this operating manual is a basic prerequisite for safe operation and safe working Please contact your customer service in case of do...

Страница 8: ...ld be carried out only by skilled personnel Never bypass or switch off fuses Adhere to the correct current specification while changing the fuses Keep moisture away from live parts as it can lead to s...

Страница 9: ...nd in stallation instructions are integral parts of this product and must be kept accessible at all times in the immediate vicinity of the control unit The device can have more or less connection opti...

Страница 10: ...lation and Operating Manual Version V 1 02 2 Installation instructions 2 1 Schematic connection of the components Sauna area Control unit Sauna Steam bath dry and frost free room Connect Box Fig 1 Sch...

Страница 11: ...Installation instructions Installation and Operating Manual Version V 1 02 11 2 2 Installing the interface converter Fig 2 Installing FCU EXT APP CONTROL CONVERTER...

Страница 12: ...er USB cable 3 1 1 Connect Box Fig 3 Connect Box front panel Fig 4 Connect Box rear view The LAN and USB ports are located on the front panel This USB port is for connecting to the interface converter...

Страница 13: ...n Connect the LAN cable from the Connect Box to your in house network LAN This connection can be made to a router or network switch Only for WLAN operation Ensure that you have stable WLAN reception I...

Страница 14: ...ou are still connected to the WLAN CONNECT BOX Note After a repeated connection with CONNECT BOX the password may be saved and does not have to be entered again 3 On your Smartphone Tablet open the In...

Страница 15: ...ortant access code for your sauna Your access code is unique to your sauna control unit and gives you and others access to your sauna Please keep it safe and do not pass it on to third parties This ac...

Страница 16: ...unction of the sys tem in the event of a violation We can detect a change In such a case there will be a charge for repairing the software 3 7 Use of the sub user function The sub user function create...

Страница 17: ...in 1 to Pin 1 cable configuration straight through WLAN frequency band 2 4 GHz 5 Structure and function 5 1 Function Depending on the variant of the FCUxxxx control unit the following bath modes can b...

Страница 18: ...Flashing blue orange The timer is active Bath mode starts at the set time Key Bath mode Sauna with humidity Functions as described for Bath mode Sauna key Key Bath mode Infrared Functions as described...

Страница 19: ...lowing symbols can appear in the status bar Display elements Description Heating time Remaining heating time Light is active Fan is active Fragrance pump is active Drying program is active Water defic...

Страница 20: ...s For this reason Perform all operating steps precisely as described in this operating manual Risk of fire WARNING Risk of injury due to fire Objects on the heater or in the immediate vicinity of the...

Страница 21: ...y key to switch on the sauna control unit See page 18 2 Select bath mode on the display see Table 2 3 To start the bath mode press and hold the bath mode key until the key lights up orange see Table 2...

Страница 22: ...umidity The values are also shown as icons in the display 4 To adjust the heating period press and hold the section Heating period Remain ing heating period until the menu opens NOTE The program autom...

Страница 23: ...ess and hold the key to open the coloured light set tings Aroma settings optional Opens the aroma settings menu Bench heating settings optional Press the key briefly to switch the bench heating on off...

Страница 24: ...tive aroma pump in minutes and the aroma pump with active injection in seconds 1 Touch one of the time fields to enable 2 Enter the preferred time in the number field 3 The value is saved once you pre...

Страница 25: ...rward The following information is shown 1 Info This shows the control unit s hardware and software version 2 Configuration This shows the control unit s basic configuration 3 Inputs and outputs This...

Страница 26: ...For this reason In case of faults switch off the control unit disconnect it from the mains and secure against restarting Contact customer service Repair work must be carried out only by qualified per...

Страница 27: ...tablished Pay attention to the beep confirmation Operator Water deficiency Evaporator without water Fill water according to the operating manual of the evaporator Operator Check water inlet magnetic v...

Страница 28: ...uit Check cable Check clamps 31 and 32 Qualified electri cian service en gineer 211 Interruption in bench sensor Cable breakage in the bench sensor Clamp contacts Check cable Check clamps 31 and 32 Qu...

Страница 29: ...ispose of the sauna control unit with regular garbage Dispose the control system in accordance with the respective country specific regulations 10 General 10 1 Limitation on liability All the specific...

Страница 30: ...ght pro tected and are subject to the commercial copyright laws Any misuse is punishable by law Distribution of any kind even in parts as well as reproduction and or sharing the con tent without the p...

Страница 31: ...ty 30 01 F 80 09 F Operating time 00 15 h 06 00 20 00 Drying temperature 80 C 110 C Drying time 0 59 min Humidity temp sum according to VDE characteristic EN 60335 2 53 2003 A1 2007 image 101 11 3 Adj...

Страница 32: ...laration of Conformity The electronics mounted in the device series FCU6xxx is identical to the certified device series FCU4xxx You will find the current declaration of conformity online at www fasel...

Страница 33: ...TROL CONVER 11 Intended use 6 Interface converter 13 L Limitation on liability 29 M Main switch 17 Mains adapter 13 Maintenance 25 Menu Aroma 24 Basic settings 24 Coloured light 24 Info menu 25 Settin...

Страница 34: ......

Страница 35: ......

Страница 36: ...Address of the installer or the dealer of the sauna sys tem...

Отзывы: