Fasel Elektronik FCU3000 Series Скачать руководство пользователя страница 16

 

 

 Technical data 

 

 

16 

Installation and Operating Manual / Version V 1.02 

 

The access code is on the supplement! 
For sub-user access you do not need an access code. 

6.  The App automatically connects to your sauna. 

7.  The sauna is additionally protected with a PIN. This is the same for all users. 

As delivered, this PIN is set to "0000". 

8.  You will be asked to assign a PIN when you connect for the first time.  

Please make a note of this PIN. It can be reset only on a sauna control unit with an 
operating element or by a service engineer! 

9.  To disconnect, open the side menu and press  

  

10. You can access your sauna at any time via "Known devices". 

 

 

 

 

 

NOTE! 

In addition, a protection module is installed to protect against changes 
to the software components. Any change by the sales department or 
end customer is prohibited and will lead to a loss of function of the sys-
tem in the event of a violation. We can detect a change. In such a case, 
there will be a charge for repairing the software. 

 

 

3.7 

Use of the sub-user function 

The sub-user function creates secure and controlled access for other people. The ac-
cess included with the App-Control is always the main user. The main user will be able 
to create and delete further accesses. For safety reasons, only the main user has this 
authorisation. 
To create a sub-user, proceed as follows: 

1.  Connect to your sauna as the main user in the App. 

2.  Select the menu item User 

 in the side menu 

3.  Use 

 to add another user. 

4.  The corresponding access is displayed as a QR code. 

5.  You can also remove a user with 

 

Note: A user who has been deleted cannot be restored. 

 

The corresponding user will no longer have access to the sauna. 

 

Technical data  

Description 

Type 

Max. distance FCUxxxx to 
CONNECT BOX 

3m USB cable 

Power supply 

Only with the enclosed USB mains adapter 

Ambient temperature 

0 to +40 °C 

Rel. humidity 

max. 80 % rel. humidity, not condensing 

Содержание FCU3000 Series

Страница 1: ...an be combined with the following sauna control units in the FCU series Series FCU3000 FCU3200 FCU3400 Series FCU4000 FCU4200 FCU4400 Series FCU5000 FCU5200 FCU5400 Series FCU6000 FCU6200 FCU6400 Doc...

Страница 2: ......

Страница 3: ...3 Interface converter 13 3 1 4 USB cable 13 3 2 Connection and initial operation 13 3 3 Initial set up with LAN operation 13 3 4 Initial set up with WLAN operation 14 3 5 Switching off or restarting t...

Страница 4: ...n the display 27 8 3 Acknowledge message 27 8 4 Error messages 27 8 5 Acknowledge error message 29 9 Decommissioning and disposal 29 10 General 29 10 1 Limitation on liability 29 10 2 Copyright protec...

Страница 5: ...order to avoid any accidents personal injuries and damage to property DANGER shows an imminently hazardous situation that can result in severe injuries or even death if not avoided WARNING shows a pot...

Страница 6: ...is not affected by cold air flowing in from the outside 1 3 Intended use The FASEL sauna control units in the FCUxx00 series are designed exclusively for op eration and control of sauna cabins saunas...

Страница 7: ...Adherence to all the safety and operating instructions specified in this operating manual is a basic prerequisite for safe operation and safe working Please contact your customer service in case of do...

Страница 8: ...ld be carried out only by skilled personnel Never bypass or switch off fuses Adhere to the correct current specification while changing the fuses Keep moisture away from live parts as it can lead to s...

Страница 9: ...nd in stallation instructions are integral parts of this product and must be kept accessible at all times in the immediate vicinity of the control unit The device can have more or less connection opti...

Страница 10: ...lation and Operating Manual Version V 1 02 2 Installation instructions 2 1 Schematic connection of the components Sauna area Control unit Sauna Steam bath dry and frost free room Connect Box Fig 1 Sch...

Страница 11: ...Installation instructions Installation and Operating Manual Version V 1 02 11 2 2 Installing the interface converter Fig 2 Installing FCU EXT APP CONTROL CONVERTER...

Страница 12: ...er USB cable 3 1 1 Connect Box Fig 3 Connect Box front panel Fig 4 Connect Box rear view The LAN and USB ports are located on the front panel This USB port is for connecting to the interface converter...

Страница 13: ...n Connect the LAN cable from the Connect Box to your in house network LAN This connection can be made to a router or network switch Only for WLAN operation Ensure that you have stable WLAN reception I...

Страница 14: ...ou are still connected to the WLAN CONNECT BOX Note After a repeated connection with CONNECT BOX the password may be saved and does not have to be entered again 3 On your Smartphone Tablet open the In...

Страница 15: ...ortant access code for your sauna Your access code is unique to your sauna control unit and gives you and others access to your sauna Please keep it safe and do not pass it on to third parties This ac...

Страница 16: ...unction of the sys tem in the event of a violation We can detect a change In such a case there will be a charge for repairing the software 3 7 Use of the sub user function The sub user function create...

Страница 17: ...in 1 to Pin 1 cable configuration straight through WLAN frequency band 2 4 GHz 5 Structure and function 5 1 Function Depending on the variant of the FCUxxxx control unit the following bath modes can b...

Страница 18: ...Flashing blue orange The timer is active Bath mode starts at the set time Key Bath mode Sauna with humidity Functions as described for Bath mode Sauna key Key Bath mode Infrared Functions as described...

Страница 19: ...lowing symbols can appear in the status bar Display elements Description Heating time Remaining heating time Light is active Fan is active Fragrance pump is active Drying program is active Water defic...

Страница 20: ...s For this reason Perform all operating steps precisely as described in this operating manual Risk of fire WARNING Risk of injury due to fire Objects on the heater or in the immediate vicinity of the...

Страница 21: ...y key to switch on the sauna control unit See page 18 2 Select bath mode on the display see Table 2 3 To start the bath mode press and hold the bath mode key until the key lights up orange see Table 2...

Страница 22: ...umidity The values are also shown as icons in the display 4 To adjust the heating period press and hold the section Heating period Remain ing heating period until the menu opens NOTE The program autom...

Страница 23: ...ess and hold the key to open the coloured light set tings Aroma settings optional Opens the aroma settings menu Bench heating settings optional Press the key briefly to switch the bench heating on off...

Страница 24: ...tive aroma pump in minutes and the aroma pump with active injection in seconds 1 Touch one of the time fields to enable 2 Enter the preferred time in the number field 3 The value is saved once you pre...

Страница 25: ...rward The following information is shown 1 Info This shows the control unit s hardware and software version 2 Configuration This shows the control unit s basic configuration 3 Inputs and outputs This...

Страница 26: ...For this reason In case of faults switch off the control unit disconnect it from the mains and secure against restarting Contact customer service Repair work must be carried out only by qualified per...

Страница 27: ...tablished Pay attention to the beep confirmation Operator Water deficiency Evaporator without water Fill water according to the operating manual of the evaporator Operator Check water inlet magnetic v...

Страница 28: ...uit Check cable Check clamps 31 and 32 Qualified electri cian service en gineer 211 Interruption in bench sensor Cable breakage in the bench sensor Clamp contacts Check cable Check clamps 31 and 32 Qu...

Страница 29: ...ispose of the sauna control unit with regular garbage Dispose the control system in accordance with the respective country specific regulations 10 General 10 1 Limitation on liability All the specific...

Страница 30: ...ght pro tected and are subject to the commercial copyright laws Any misuse is punishable by law Distribution of any kind even in parts as well as reproduction and or sharing the con tent without the p...

Страница 31: ...ty 30 01 F 80 09 F Operating time 00 15 h 06 00 20 00 Drying temperature 80 C 110 C Drying time 0 59 min Humidity temp sum according to VDE characteristic EN 60335 2 53 2003 A1 2007 image 101 11 3 Adj...

Страница 32: ...laration of Conformity The electronics mounted in the device series FCU6xxx is identical to the certified device series FCU4xxx You will find the current declaration of conformity online at www fasel...

Страница 33: ...TROL CONVER 11 Intended use 6 Interface converter 13 L Limitation on liability 29 M Main switch 17 Mains adapter 13 Maintenance 25 Menu Aroma 24 Basic settings 24 Coloured light 24 Info menu 25 Settin...

Страница 34: ......

Страница 35: ......

Страница 36: ...Address of the installer or the dealer of the sauna sys tem...

Отзывы: