SETUP COMMANDS
Command
Function
SZ# Image
Size
(0=Cropped, 1=Normal)
S#
Scan Rate (0-8)
0= Line Doubled
1= Frame Doubled*
2= 800x600
3= 720p
4= 1024x768
5= Line Quadrupled (960p)
6= 1280x1024
7= 1080p
8= 1080i
W#
Screen Shape,
(0=Widescreen, 1=4x3)
Fn
Input Video Standard
0=1=Auto,2=PALN 3=PALM
M#
Output Mode (0-2)
(0=RGB, 1=YCrCb, 2=YPrPb)
CS#
Comp Sync (1=On)
G#
Sync on Green (1=On)
HS#
HD Pass Scan Rate (0-7)
0= 800X600
1= 1024X768
2= 1280X1024
3= 1600X1200
4= Custom 1
5= Custom 2
6= HDTV (720p or 1080i)
7= WVHS
HF#
HD Frame Rate (0-2)
0 = 60Hz
1 = 75Hz
3 = 85Hz
HDS#
HDTV Sync (0 = HV, 1 = C)
HDUC
HD Converter On/Off (1 = On)
OSDON
Turn OSD On
OSDOFF
Turn OSD Off
OV#
OSD Vertical Start (0 = top)
E0/E1 ECHO
OFF/ON
SET
Save Setup To All
OPERATION COMMANDS
ON/OFF Power
ON/OFF
HELP
Display Help Menu
ST Report
Current
Status*
V
Video
Y
Y/C
X
YCrCb
HD
HDTV Input
HDIN#
HDTV Input Format
(0 = RGB, 1 = YUV, 2 = YPrPb)
HDP
HDTV Passthrough Input
B#
Brightness (0-255)
C#
Contrast (0-255)
K#
Color (0-255)
T#
Tint (0-255)
N#
Noise Reduction (0-15)
D#
Detail (0-15)
A#
Input Aspect Ratio (0-2)
(0=4x3, 1=Letterbox, 2=Anamorphic)
L#
Store User Preset (1-4)
P#
Recall Preset (0-4)
(1-4=User, 0=Factory)
P5 in the ST means something changed since
the last preset was recalled.
Infrared Control Notice:
All commands via
Infrared are direct access. The Power On/Off
control is a two command macro. The second
command must occur within .25 seconds of the
first command.
On Power,
Value
Up
Off
Power, Value Dow
13
RS232 INSTRUCTIONS