FARO Gage
May 2011
39
Chapter 6: Maintenance and Troubleshooting
ESD Lotion
- ESD lotion provides a better connection between the user and a
smock, heel strap or wrist strap. This may need to be reapplied if the smock or
straps are removed.
Smocks
- ESD smocks are designed to dissipate static fields created by a
wearer’s shirt. These must be worn at all times within an ESD Sensitive area. All
buttons must be secured when working. Smocks are to be connected to an ESD
ground point (never earth ground) or to a grounded mat. While the smock is
connected and properly grounded, wrist straps are unnecessary.
ESD Chairs
- ESD chairs have a ground strap which comes in contact with a
grounded mat or conductive flooring and dissipates charges safely to ground.
Table Mats
- Table mats are made of a dissipative material and must be
grounded individually to earth ground.
Hand Tool Requirements
- Hand tools must be stored in non-insulating or
charging stations. New hand tools should be ESD-safe (non-generating and
dissipative).
Floor Mats
- Floor mats are made of a dissipative material and must be grounded
individually to earth ground. This is required if no conductive flooring is
installed.
Ground Connections
- Any earth ground connection is sufficient.
Conductive Flooring
- Conductive flooring must be installed per manufacturer
specifications and be connected to earth ground.
Wrist/Heel Strap Tester
- These provide a method for checking the function of
smocks, heels straps and cable connections on an individual user.
Ionizers
- An Ionizer floods the air with positive and negative ions, which
eliminate static charges. This must be installed so that the airflow blows across
the workbench (or down on the workbench for overhead units).
Constant Ground Monitors
- Constant monitors are connected to a workstation
mat and operator and will sound an audible alarm if any ground is interrupted.
Troubleshooting
Error message on host computer.
• Contact FARO’s Customer Service by Phone, Fax or E-Mail.
Have the message ready.
Probe compensation fails.
• Check that the diameter stamped on the probe tip matches the tip of the
current probe.
08M47E00_FAROGage.book Page 39 Wednesday, June 8, 2011 4:12 PM
Содержание Gage
Страница 1: ...FARO Gage Manual MAY 2011 08M47E00_FAROGage book Page 1 Wednesday June 8 2011 4 12 PM...
Страница 2: ...08M47E00_FAROGage book Page 2 Wednesday June 8 2011 4 12 PM...
Страница 4: ...08M47E00_FAROGage book Page 4 Wednesday June 8 2011 4 12 PM...
Страница 8: ...08M47E00_FAROGage book Page iv Wednesday June 8 2011 4 12 PM...
Страница 32: ...08M47E00_FAROGage book Page 24 Wednesday June 8 2011 4 12 PM...
Страница 38: ...08M47E00_FAROGage book Page 30 Wednesday June 8 2011 4 12 PM...
Страница 60: ...08M47E00_FAROGage book Page 52 Wednesday June 8 2011 4 12 PM...
Страница 74: ...08M47E00_FAROGage book Page 66 Wednesday June 8 2011 4 12 PM...
Страница 78: ...08M47E00_FAROGage book Page 70 Wednesday June 8 2011 4 12 PM...
Страница 94: ...08M47E00_FAROGage book Page 6 Wednesday June 8 2011 4 12 PM...
Страница 102: ...08M47E00_FAROGage book Page 4 Wednesday June 8 2011 4 12 PM...
Страница 103: ...08M47E00_FAROGage book Page 1 Wednesday June 8 2011 4 12 PM...