![FARMSCAN Jackal v2 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/farmscan/jackal-v2/jackal-v2_manual_3479456022.webp)
July 2013
more quick guides @ www.farmscanag.com/jackal
AM-Jackal-2
20
Other Settings
OTHER SETTINGS
FRONT SCREEN > SETUP > OTHER SETTINGS
Use to setup Implement width for display Ha/Ac, Enable/Disable remote run/hold function & audible alarm
notifications
If you wish to display Ha/Ac on the front screen you
need to have an implement width set. By default the
Jackal displays 8m.
You can adjust the implement with and choose your
UOM (M, FT, YD, IN, KM, MI).
If the UOM & implement widths remain untouched the
Jackal will not display the information unless specified
in the FRONT SCREEN setup.
By changing the Alarm Beep you can define how many
audible “Beeps” can be heard during the Alarm alert.
The EXTERNAL RUN/HOLD function can be used to
disable all accumulating values and alarms set in the
Jackal. It duplicates the operation of the RUN/HOLD
button available on the front screen.
NOTE – When the EXTERNAL RUN / HOLD is active on
ANY input the function of the RUN /HOLD button on
the front screen is disabled.
Input of the switching function to active the EXTERNAL RUN/HOLD can be applied to any of the 13 available
inputs on the Jackal. To enable maximum flexibility for this function NORMALLY ON or NORMALLY OFF mode can
be selected for this function.
These are described below:
When a circuit exists between the selected input and
ground (GND), selecting
NORMALLY ON
will result in
the Jackal going into HOLD mode
Selecting
NORMALLY OFF
will result in the reverse i.e.
the JACKAL will be in RUN mode until the circuit is
broken after which it will go into HOLD mode.
After you select the desired hold method select the INPUT# port that is being used to detect Run/hold
Disabled : External Run/Hold is not used. Use the Run/Hold (2/3) button only.