background image

EN

 Operating instructions

Содержание Wile 25

Страница 1: ...EN Operating instructions ...

Страница 2: ...bes needs to be ordered separetly The meter shows the water content of the sample in percentage of weight The definition of moisture is based on measuring the loss of a high frequency alternating current signal capacitance in the sample The repeatability of the result is 2 0 percent of moisture or better Wile 25 meter is calibrated to give uniform results with the official methods that are used fo...

Страница 3: ...ng time Replace battery See 6 Battery Read this manual Check you meter See 5 Control care and maintenance 3 1 1 Bales and measurements In big bales the chances of varying moisture is greater so always make 5 readings per bale to get an average In small traditional bales it is normally enough to do one measurement Always double check any high readings when you deal with dry hay or straw If you find...

Страница 4: ...utbound product at the factory Probe 3 wile 253 for loose hay Wile 253 dishprobe for loose silage or hay Measuring in a bucket see 3 2 1 loose hay 3 2 Processing the sample and using the probe 3 2 1 Loose hay Always do several measurements of the chosen batch Take a handful from different plases of the swoth and fill a bucket Press the hay or silage in to dense layers in the bucket with your hand ...

Страница 5: ...r bales you need to have several measurements Take the readings from different spots from the bale When measuring round bales you need to take readings from several spots You need to estimate the density of the bale to get correct moisture readings 3 2 3 Define the density of the bale To define the density you need to know the weight and volume of the bale Divide the weight of the bale kg with its...

Страница 6: ...g to chapter 3 4 1 Choosing probe in the meter The meter will now show you the densityreading When needed change densityreading according to chapter 3 4 2 density settings The meter starts measuring and shows moisturereadings shortly The meter considers thetemperature of the sample and how it effects the moisturereadings The meter turns off itself after the measuring Always do several measurings c...

Страница 7: ... meter The liste of the availalble probes is on the side of the meter Choose the right probe Ther is also a probe 0 basic scale that wile service will use Probe 0 is a basic scale that can also be used for table scales When using Probe 0 you do an ordinary measuring and see the identical mositurereadings from the table You will get the tablescales from the manufacturer or the local wile dealer als...

Страница 8: ...ng F and increase 10 kg m3 by every press 250 is the last value 4 Processing of the results 4 1 Average calculation The meter can store and calculate an av erage value of several measurements After a measurement you can add the result to the average calculation 4 1 1 Adding a result to the average calculation When the result is shown on the display Press F Now A will be on the display the meter ha...

Страница 9: ...t A00 Method 2 Press F and keep it depressed then press P When you see A on the display release the F button If you now see an average value you can erase it by keeping the button F depressed until you see on the display 0 and after that A00 Please note It is a good practice to erase the average memory after completing a measuring session This prevents any old values affecting later measurements T...

Страница 10: ... from the result Press F three times when the result is on the display Three bars will appear on the bottom of the display and after that the moisture reading Now deduct 0 1 percent from the result with each press of F Please note The adjustment of the calibration is specific for each probe 4 2 3 Adjustment of the calibration An adjustment to the calibration will appear on the display after the ne...

Страница 11: ... the lower limit of the measurement range Moiture range for loose hay is between 13 85 and 10 73 for baled hay When getting HI or LO result always check that you are using right probe and also do some checkmeasurings 5 Control care and maintenance All Wile 25 moisture meters are calibrated when manufactured Before the season starts check the meters basic functions After pressing P it should read A...

Страница 12: ... The meter works with a 9 volt 6F22 battery or an alkaline battery of the same format A battery is included in the delivery LOBAT sign at the upper left corner of the display indicates that the battery should be replaced Replace the battery as soon as possible If the battery is nearly empty the LOBAT sign may not be seen any more To replace the battery open the lid of the battery compartment in th...

Страница 13: ...n The manufacturer Wile Service Partner will repair or replace the defect product and return it as soon as possible The warranty does not cover any damages that are caused by incorrect or careless use of the product installation that does not correspond to the provided instructions and other damages which may arise due to causes beyond the control of the manufacture Farmcomp does not accept any re...

Страница 14: ... Model numbers Wile 25 conforms to the EMC directive 2004 108 EC by following the harmonised standard EN 61326 1 2006 Tuusula Finland Lasse Paakkola July 22 2010 Managing Director Original language Finnish Signed Declaration of Conformity documents are filed at Farmcomp Oy Farmcomp Oy Jusslansuora 8 FIN 04360 Tuusula Finland tel 358 9 77 44 970 e mail info farmcomp fi Company ID FI 07308235 Tuusul...

Страница 15: ...FARMCOMP OY Jusslansuora 8 TUUSULA FINLAND Tel 358 9 7744 970 Fax 358 9 7744 9744 FI 04360 info farmcomp fi http www wile fi Copyright Farmcomp Oy 2010 all rights reserved ...