- 9
-
Mi 2380/2
IT
ALIANO
EN
GLISH
FR
ANÇAIS
ES
PAÑOL
P
OR
T
UGUÊS
DE
UTSCH
- see Table 1); on the picture below
the dip-switches MS1 and MS2 are
configured for address assignment
201:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
EC/EM programming for second
camera control (codes 178 and
225).
(Factory default not set for second
camera).
Please refer to the appli-
cation diagram on page 5 for con-
nections.
Once in programming:
by the dip-switches
MS1
and
MS2,
set the code 178 for the first fun
-
ction:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button;
by the dip-switches
MS1
and
MS2,
set the value 066:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button.
by the dip-switches
MS1
and
MS2,
set the code 225 for the second
function:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button;
by the dip-switches
MS1
and
MS2,
set the value 255:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
Disabling line free tone (code 17
8).
(Factory enabled).
Once in program-
ming:
by the dip-switches
MS1
and
MS2,
set the function code 178:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button;
by the dip-switches
MS1
and
MS2,
set the value
074
(in
case EC/EM
are used to control the second
camera
):
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
or the value
010
(in
case EC/EM are
not used to manage the second
camera
):
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button.
If no further settings are required,
exit programming or continue with
the following paragraphs.
Restore factory settings (code
170).
The return to the factory settings can
be performed via Bluetooth or ma-
nually as indicated below, once pro-
gramming has been entered:
by the dip-switches
MS1
and
MS2,
set the function code 170:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button;
by the dip-switches
MS1
and
MS2,
set the value 085:
ON
1
2
3
4
MS1
ON
1
2
3
4
MS2
press the
SW
confirmation button.
Restoring factory default in
the CD2131PL, CD2132PL and
CD2138PL will bring them to the
behaviour of a CD2134PL. This
should be taken into account
and, if necessary, access via
Bluetooth and configure the
“Digital Encoder operating
mode” option correctly.
OPERATION
To make a call press the button
corresponding to the desired user.
Call is confirmed by an acknowledge
tone, if the line is free, or denied by
a busy tone if the line is busy. Called
equipment rings only once, but if in this
phase the same button on the external
station is pressed again the equipment
will ring again.
As soon as the called user picks up the
handset enables the conversation with
the external station for 90 seconds.
A tone will notify the user 10 seconds
before the conversation ends. To
continue conversation for additional
90 seconds the calling button must be
pressed again on the external station.
On the internal station, press the
button to release the door lock. Door
lock activation time is 3 seconds (or
6 seconds according to the system
programming, only via Bluetooth).
Replace the handset at the end of the
conversation to restore the idle state.