background image

- 9

 -

Mi 2380/2

IT

ALIANO

EN

GLISH

FR

ANÇAIS

ES

PAÑOL

P

OR

T

UGUÊS

DE

UTSCH

- see Table 1); on the picture below 

the dip-switches MS1 and MS2 are 

configured for address assignment 

201:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

     

       

 

press the 

SW 

 confirmation button.

If no further settings are required, 

exit programming or continue with 

the following paragraphs.

EC/EM programming for second 

camera control (codes 178 and 

225). 

 

 

 

 

 

                               

  

(Factory default not set for second 

camera).

 Please refer to the appli-

cation diagram on page 5 for con-

nections.

Once in programming:

 

by the dip-switches 

MS1 

and 

MS2, 

set  the  code  178  for  the  first  fun

-

ction:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

 

 

press the 

SW 

 confirmation button;

 

by the dip-switches 

MS1 

and 

MS2, 

set the value 066:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

     

       

 

press the 

SW 

 confirmation button.

 

by the dip-switches 

MS1 

and 

MS2, 

set the code 225 for the second 

function:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

 

 

press the 

SW 

 confirmation button;

 

by the dip-switches 

MS1 

and 

MS2, 

set the value 255:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

     

       

 

press the 

SW 

 confirmation button.

If no further settings are required, 

exit programming or continue with 

the following paragraphs.

Disabling line free tone (code 17

8).                                                                               

                 

(Factory enabled).

 Once in program-

ming:

 

by the dip-switches 

MS1 

and 

MS2, 

set the function code 178:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

 

 

press the 

SW 

 confirmation button;

 

by the dip-switches 

MS1 

and 

MS2, 

set the value 

074 

(in 

case EC/EM 

are used to control the second 

camera

):

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

    

 

     

or the value 

010 

(in 

case EC/EM are 

not used to manage the second 

camera

):

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

 

  

 

press the 

SW 

 confirmation button.

If no further settings are required, 

exit programming or continue with 

the following paragraphs.

Restore factory settings (code 

170). 

 

 

 

                                          

                                                 

The return to the factory settings can 

be performed via Bluetooth or ma-

nually as indicated below, once pro-

gramming has been entered:

 

by the dip-switches 

MS1 

and 

MS2, 

set the function code 170:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

 

 

press the 

SW 

 confirmation button;

 

by the dip-switches 

MS1 

and 

MS2, 

set the value 085:

 

ON

1

2

3

4

MS1

ON

1

2

3

4

MS2

     

       

 

press the 

SW 

 confirmation button.

 

Restoring factory default in 

the CD2131PL, CD2132PL and 

CD2138PL will bring them to the 

behaviour of a CD2134PL. This 

should be taken into account 

and, if necessary, access via 

Bluetooth  and  configure  the 

“Digital Encoder operating 

mode” option correctly.

OPERATION

To make a call press the button 

corresponding to the desired user. 

Call is confirmed by an acknowledge 

tone, if the line is free, or denied by 

a busy tone if the line is busy. Called 

equipment rings only once, but if in this 

phase the same button on the external 

station is pressed again the equipment 

will ring again.

As soon as the called user picks up the 

handset enables the conversation with 

the external station for 90 seconds. 

A tone will notify the user 10 seconds 

before the conversation ends. To 

continue conversation for additional 

90 seconds the calling button must be 

pressed again on the external station.

On the internal station, press the 

 

button to release the door lock. Door 

lock activation time is 3 seconds (or 

6 seconds according to the system 

programming, only via Bluetooth).

Replace the handset at the end of the 

conversation to restore the idle state.

Содержание PROFILO Series

Страница 1: ...P DUO line EC EM command for services S1 S2 door opening relay contact FR DIGITALISEUR SERIE PROFILO Permetd adresserdesappelssurligne digitale DUO Donn es techniques Alimentation du module audio vid...

Страница 2: ...2 IT ALIANO EN GLISH FR AN AIS ES PA OL P OR T UGU S DE UTSCH Mi 2380 2 IT INSTALLAZIONE EN INSTALLATION FR INSTALLATION ES INSTALACI N PT INSTALA O DE INSTALLATION...

Страница 3: ...cable para la conexi n al m dulo de audio v deo cabo para a liga o ao m dulo udio v deo Kabel f r den Anschluss an die Sprecheinheit MS2 MS1 microinterruttori di programmazione MS2 MS1 programming mi...

Страница 4: ...ssible de la charge th oriquement sur les terminaux de la charge m me ES Cerradura el ctrica Como se ve en los siguientes diagramasdeinstalaci n lacerradura el ctrica se puede accionar por el mismo al...

Страница 5: ...ionnel Pulsador abrepuerta opcional Bot o para abrir a porta opcional Zus tzliche T r ffnertaste Erg nzung SE Serratura elettrica 12Vca 1A max Electric door lock 12VAC 1A max G che lectrique 12Vca 1A...

Страница 6: ...EM MS1 SW MS2 Ad ogni pressione del tasto SW un tono di conferma o di errore indicher l immissione di un codice corretto o sbagliato nel secondo caso sar necessario reinserire il codice esatto Progra...

Страница 7: ...4 MS1 ON 1 2 3 4 MS2 premere il tasto di conferma SW tramite i microinterruttori MS1 e MS2 impostare il valore 074 nel caso in cui EC EM siano utilizzati per la gestione della seconda te lecamera ON 1...

Страница 8: ...ed Door station address program ming code 177 Factory setting 231 Once in pro gramming by the dip switches MS1 and MS2 set the function code ON 1 2 3 4 MS1 ON 1 2 3 4 MS2 press the SW confirmation but...

Страница 9: ...are not used to manage the second camera ON 1 2 3 4 MS1 ON 1 2 3 4 MS2 press the SW confirmation button If no further settings are required exit programming or continue with the following paragraphs R...

Страница 10: ...le bouton de confirma tion SW ON 1 2 3 4 ON 1 2 3 4 J1 1 2 3 S1 S2 EC EM MS1 SW MS2 Chaque fois que vous appuyez sur le bouton SW une tonalit de confir mation ou d erreur indique si un code correct ou...

Страница 11: ...ogrammation sur les micro interrupteurs MS1 et MS2 r gler le code de la fonction ON 1 2 3 4 MS1 ON 1 2 3 4 MS2 appuyez sur le bouton de confirma tion SW sur les micro interrupteurs MS1 et MS2 r gler l...

Страница 12: ...n de confirmaci n SW ON 1 2 3 4 ON 1 2 3 4 J1 1 2 3 S1 S2 EC EM MS1 SW MS2 Cada vez que se pulse el bot n SW un tono de confirmaci n o de error in dicar si se ha introducido un c digo correcto o incor...

Страница 13: ...1 2 3 4 MS1 ON 1 2 3 4 MS2 pulsar el bot n de confirmaci n SW en los microinterruptores MS1 y MS2 ajustar el valor 074 si se uti lizan EC EM para gestionar la se gunda c mara ON 1 2 3 4 MS1 ON 1 2 3 4...

Страница 14: ...1 2 3 4 J1 1 2 3 S1 S2 EC EM MS1 SW MS2 Cada vez que o bot o SW premido um tom de confirma o ou de erro indicar se foi introduzido um c digo correcto ou incorrecto neste ltimo caso o c digo correcto d...

Страница 15: ...1 2 3 4 MS2 pressione o bot o de confirma o SW usando os microswitches MS1 e MS2 definir o valor 074 no caso de serem utilizados EC EM para gerir a segunda c mara ON 1 2 3 4 MS1 ON 1 2 3 4 MS2 ou o va...

Страница 16: ...rden soll dr cken Sie die SW Best tigungs taste ON 1 2 3 4 ON 1 2 3 4 J1 1 2 3 S1 S2 EC EM MS1 SW MS2 Jedes Mal wenn die SW Taste ge dr ckt wird zeigt ein Best tigungs oder Fehlerton an ob ein richtig...

Страница 17: ...ie Programmierung oder fahren Sie mit den folgenden Abschnitten fort Ausschalten des Freitons Code 178 werkseitig aktiviert Einmal in der Programmierung Stellen Sie an den Mikroschaltern MS1 und MS2 d...

Страница 18: ...3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 42 41 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 MS1 MS2 O...

Страница 19: ...ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2...

Страница 20: ...2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 MS1 MS2 ACI srl Farfisa Intercoms ViaE Vanoni 3 60027Osimo AN Italy Tel 39 071 7202038 r a Fax 39 071 72...

Отзывы: