USE AND MAINTENANCE MANUAL - SECTION 3
AERIAL PLATFORM ELEVAH 65-80 ES MOVE
– Rev. 03_2019
Page 3-3
FUNCTIONAL TEST
At the end of the "DAILY INSPECTION" (section n°6), carry out a functional
test of all plants in an area free from overhead obstacles and at ground level.
ATTENTION
IF THE MACHINE DOES NOT WORK PROPERLY, SWITCH IT OFF
IMMEDIATELY. ALERT MAINTENANCE PERSONNEL TO THE PROBLEM.
DO NOT USE THE MACHINE UNTIL IT IS DEEMED SAFE TO USE.
Carry out a functional test as detailed below.
1. From the ground controls
a.
Check the correct operation of the manual emergency descent
valve;
b.
Lift and lower the basket checking lifting and lowering happen
regularly;
c.
Make sure all machine functions are disabled when operating
(pressing) the emergency stop button.
2. From the control console of the basket
a.
Lift and lower the basket checking lifting and lowering happen
regularly;
b.
Activate all functions and check the correct operation of all end run
switches, main and activation switches:
•
Machine brakes
(on self-propelled machine)
– Drive the
machine on a slope (not exceeding the nominal operational
capacity on a slope) and stop it to ensure the brakes hold it;
Содержание ELEVAH 65 ES MOVE
Страница 73: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ELEVAH 65 80 ES MOVE Rev 03_2019 Page 9 3 1 1 11 3 5...
Страница 75: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ELEVAH 65 80 ES MOVE Rev 03_2019 Page 9 5 7 1 1 13 3...
Страница 76: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ELEVAH 65 80 ES MOVE Rev 03_2019 Page 9 6 1 1 8 13 6 7...
Страница 78: ...USE AND MAINTENANCE MANUAL SECTION 9 AERIAL PLATFORM ELEVAH 65 80 ES MOVE Rev 03_2019 Page 9 8...
Страница 82: ...NOTES...
Страница 83: ......