background image

4

Your new ceiling fan will require a grounded electrical 
supply line of 120 volts AC, 60 Hz, 15 amp circuit. The 
outlet box must be securely anchored and capable of 
withstanding a load of at least 35lbs.

Figure 1

depicts

different structural configurations that may be used for 
mounting the outlet box.

Ceiling

Ceiling

Joists

Figure 1

WARNING

To avoid fire or shock, follow all wiring instructions 
carefully.  Any electrical work not described in these 
instructions should be done or approved by a licensed 
electrician.

WARNING

Turning off wall switch is not sufficient.

To avoid 

possible electrical shock, be sure electricity is turned 
off at the main fuse box before wiring.  All wiring must 
be in accordance with National and Local codes and the 
ceiling fan must be properly grounded as a precaution 
against possible electrical shock.

WARNING

To reduce the risk of fire, electrical shock, or personal 
injury, mount fan to outlet box marked acceptable for 
fan support of 15.9 kg (35lbs). Use screws supplied with 
outlet box. Most outlet boxes commonly used for support 
of light fixtures are not acceptable for fan support and 
may need to be replaced.  Consult a qualified electrician 
if in doubt.

Electrical and Structural Requirements

Energy Efficient Use of Ceiling Fans

Ceiling fan performance and energy savings rely 
heavily on the proper installation and use of the ceiling 
fan. Here are a few tips to ensure efficient product 
performance.

Choosing the Appropriate Mounting Location

Ceiling fans should be installed, or mounted, in the middle 
of the room and at least 7 feet above the floor and 18 
inches from the walls. If ceiling height allows, install the fan 
8 - 9 feet above the floor for optimal airflow. Consult your 
Fanimation Retailer for optional mounting accessories.

Turn Off When Not in the Room

Ceiling fans cool people, not rooms. If the room is 
unoccupied, turn off the ceiling fan to save energy.

Using the Ceiling Fan Year Round
Summer Season:

Use the ceiling fan in the counter-

clockwise direction. The airflow produced by the ceiling 
fan creates a wind-chill effect, making you “feel” cooler. 
Select a fan speed that provides a comfortable breeze, 
lower speeds consume less energy.

Winter Season:

Reverse the motor and operate the ceiling 

fan at low speed in the clockwise direction. This produces 
a gentle updraft, which forces warm air near the ceiling 
down into the occupied space.Remember to adjust your 
thermostat when using your ceiling fan - additional energy 
and dollar savings could be realized with this simple step!

2  x 4

Outlet
Box

Содержание The Zonix FP4640OB

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP4640 The Zonix Wet Location Ceiling Fan Net Weight 10 kg 22 lbs...

Страница 2: ...also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purcha...

Страница 3: ...er Motor Coupling Cover Switch Cup Cover Assembly t e S e d a l B Switch Cup Cover Assembly Hardware Bags Fan Motor Assembly Downrod Hanger Ball Assembly Hanger Bracket One Phillips head screwdriver O...

Страница 4: ...ian if in doubt Electrical and Structural Requirements Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fa...

Страница 5: ...e to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properl...

Страница 6: ...tlet box screws and washers supplied with the fan Figure 9 WARNING The outlet box must be securely anchored Hanger bracket must seat rmly against outlet box If the outlet box is recessed remove wall b...

Страница 7: ...plied 2 Securely connect the white fan motor wire to the white supply neutral wire using wire connector supplied Securely connect the black fan motor wire and blue wire to the black supply wire using...

Страница 8: ...Fan Blades and Cover Switch Cup Assembly INSTALLATION NOTE Do not connect fan blades until the fan is completely installed Installing the fan with blades assembled may result in damage to the fan bla...

Страница 9: ...ng agents are not required and should be avoided to prevent damage to finish CAUTION Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility...

Страница 10: ...r 8 Blade Set 3 AP464005 9 Hardware Bag Containing HDWFP4640 Blade Balance Kit BALKT Wire Connectors 4 Chain Coupler Chain Fob Blade Mounting Hardware Bag Containing 3 16 24 x 13 mm Phillips Head Scre...

Страница 11: ...11 6 5 The Zonix Model FP4640 Exploded View 1 3 4 2 7 NOTE The illustration shown is not to scale or its actual con guration may vary Product parts are subject to change without notice Figure 1 8 9 9...

Страница 12: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state con...

Страница 13: ......

Страница 14: ...Copyright 2011 Fanimation 2011 04 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Страница 15: ...The Zonix Ventilador de techo para ubicaciones h medas Peso neto 10 kg 22 lbs Modelo N FP4640 MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES...

Страница 16: ...ion Instrucciones de seguridad importantes ADVERTENCIA Siga estas instrucciones para prevenir incendios descargas el ctricas y lesiones personales graves Lea el manual del propietario y la informaci n...

Страница 17: ...ontacto con su tienda si faltan piezas o hay piezas da adas nidad del otor del ventilador Ca a del interruptor nidad del soporte de suspensi n nidad del barral de la se ies era Capuch n de techo Cubie...

Страница 18: ...o a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que obliga al aire c lido que se acumula cerca del techo a bajar al espacio ocupado No olvide aju...

Страница 19: ...ando hacia arriba Figura 4 5 Vuelva a colocar la semiesfera en el barral como se indica a continuaci n Pase los tres cables de a trav s de la semiesfera Pase el pasador a trav s de los dos orificios e...

Страница 20: ...dosamente el ventilador y coloque el ensamble de la bola para colgar varilla en la abrazadera para colgar que acaba de fijar a la caja de salida Aseg rese de que la ranura de la bola est alineada con...

Страница 21: ...eutro con el conector de cables suministrado Conecte el cable negro del motor del ventilador y el cable azul al cable de suministro negro con el conector de cables suministrado Figura 1 3 Luego de emp...

Страница 22: ...ilador y el interruptor de la cubierta Figura 13 NOTA DE INSTALACI N No conecte las aspas hasta que el ventilador est totalmente instalado Instalar el ventilador con las aspas colocadas podr a ocasion...

Страница 23: ...s abrasivos de limpieza los mismos deben evitarse para prevenir da os en el acabado PRECAUCI N No utilice solventes para limpiar el ventilador de techo Podr an da ar el motor o las aspas y ocasionar p...

Страница 24: ...stornillador Phillips de 4 24 AP464007 Lista de piezas Modelo N FP4640 N de Ref Descripci n Pieza N Bolsa de accesorios que contiene plana inoxidable 10 Antes de desechar los materiales de embalaje as...

Страница 25: ...Zonix Modelo FP4640 Producto partes est n sujetas a cambios sin previo aviso Figura 1 Despiece NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar 6 5 1 3 4 2...

Страница 26: ...ruptor PRECAUCI N Aseg rese de que el suministro principal de electricidad est desconectado Algunos motores de ventilador son sensibles a las 5 se ales de los controles de velocidad de estado s lido v...

Страница 27: ......

Страница 28: ...2011 Fanimation 2011 04 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fanim...

Отзывы: