background image

How to Assemble Your Ceiling Fan

Pin

Setscrew

Hanger

Ball

Figure 1

1. 

Remove the Hanger Ball by loosening the setscrew 

in the Hanger Ball until the ball falls freely down the 
Downrod. (Figure 1)  Remove the Pin from the Downrod, 
then remove the Hanger Ball.  Retain the Pin and Hanger 
Ball for reinstallation in Step 5.

2. 

The fan comes with blue, black, white 80

˝

 wires and 

safety cable. Separate & untwist the three wires and safety 
cable. Route the wires through the downrod.

NOTE: 

 You will be using either the 6

˝

 downrod supplied with 

your fan or an optional downrod purchased separately.

3.

 Loosen the two setscrews in the Downrod Support.  Align 

the Clevis Pin holes in the Downrod with the holes in the 
Downrod Support.  Install the Clevis Pin and secure with 
the Hairpin Clip. (Figure 3)  Be sure to push the straight 
leg of the hairpin clip through the hole near the end of the 
clevis pin until the curved portion of the hairpin clip snaps 
around the clevis pin.  The hairpin clip must be properly 
installed to prevent the clevis pin from working loose. Pull 
on the Downrod to make sure the clevis pin is properly 
installed.

4. 

Route wires and cable through Motor Coupling Cover 

and Canopy  on fan shown with open side facing up. 
(Figure 3)

5. 

Reinstall the Hanger Ball (Figure 1) on the Downrod 

as follows.  Route the three 80

˝

 wires and cable through 

the Hanger Ball.  Position the Pin through the two holes 
in the Downrod and align the Hanger Ball so the Pin is 
captured in the groove in the top of the Hanger Ball.  Pull 
the Hanger Ball up tight against the pin. 

Securely tighten 

the setscrew in the Hanger Ball.  A loose setscrew 
could create fan wobble.

6. 

While pulling up on the hanger ball, securely tighten the 

two 3/16-24 x 3/8

˝

 setscrews in the downrod support. Slide 

the Motor Coupling Cover down. (Figures 2 & 3)

7. 

The fan comes with blue, black, white leads and support 

cable.  Before installing fan, measure up approximately 
6-9 inches above top of Downrod/Hanger Ball Assembly.  
Cut off excess wire and strip back insulation ½

˝

 from end 

of wire.

8. 

All set screws must be checked and retightened where 

necessary before installation.

9.

 You have now completed the upper assembly of your 

new ceiling fan.  You can now proceed with the hanging 
and the electrical wiring of your fan.

Hairpin Clip

Setscrew (2)

Motor

Coupling

Cover

Figure 2

Figure 3

Clevis Pin

Downrod 

Support

WARNING

It is critical that the clevis pin in the downrod support 

is properly installed and the setscrews are securely 

tightened.  Failure to verify that the pin and setscrews 

are properly installed could result in the fan falling.

5

Содержание Levon FP7910OB

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No FP7910OB The Levon 8 Bladed Ceiling Fan Net Weight 12 0 kg 26 5 lbs...

Страница 2: ...t vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Im...

Страница 3: ...ger Ball Assembly Hanger Bracket One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Ceiling Canopy Blades Hardware bags 20 x 14mm blade...

Страница 4: ...need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the c...

Страница 5: ...wn with open side facing up Figure 3 5 Reinstall the Hanger Ball Figure 1 on the Downrod as follows Route the three 80 wires and cable through the Hanger Ball Position the Pin through the two holes in...

Страница 6: ...avoid possible shock do not pinch wires between the downrod hanger ball assembly and the hanger bracket 1 Using the 3 8 x 2 lag bolt and flat washer attach safety cable to ceiling joist or wood struc...

Страница 7: ...isted Outlet Box Black Green Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure...

Страница 8: ...the motor hub are tight and that the blade holders are properly seated Housing Switch Cup Adapter Assembly 7 Disassemble the Housing Switch Cup Adapter assembly by removing three screws Figure 4 8 Ass...

Страница 9: ...y gently pulling on the pull chain switch Figure 1 3 If airflow is desired in the opposite direction turn the fan off and wait for the blades to stop turning Then slide the reverse switch to the oppos...

Страница 10: ...o H e d a l B 7 L W 3 0 0 0 8 8 P A 8 e d a l B 8 9 Hardware Bag Containing HDWFP7910SS 5 32 Threaded Rods 2 HDWHW7910SS 5 32 External Lockwasher 2 Knurled Knobs 2 Blade Balance Kit BALKT Chain Couple...

Страница 11: ...11 6 5 7 The Levon FP7910OB Exploded View 4 8 1 3 2a 2b 2c 2d 2 NOTE The illustration shown is not to scale or its actual configuration or finishes may vary Figure 1 9...

Страница 12: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state con...

Страница 13: ......

Страница 14: ...Copyright 2009 Fanimation 2009 07 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Отзывы: