background image

5

How to Assemble Your Ceiling Fan

1.  

Prior to assembly, set aside and save the hardware 

bags packed in the packing.

2. 

 Remove the Hanger Ball by loosening the setscrew 

in the Hanger Ball until the ball falls freely down the 
Downrod. (Figure 1)  Remove the Pin from the Downrod, 
then remove the Hanger Ball.  Retain the Pin and Hanger 
Ball for reinstallation in Step 7.

3.  

The fan comes with blue, black, and white 80

˝

 wires. 

Separate and untwist the three wires.  Route the wires 
through the Downrod.

NOTE:

 You will be using either the 4½

˝

 downrod 

supplied with your fan or an optional down rod purchased 
separately.

4.

  Loosen the two setscrews in the Downrod Support. 

Install Downrod into Coupler. Align the Clevis Pin holes 
in the Downrod with the holes in the Downrod Support. 
(Figure 2)

NOTE: 

 The clevis pin and setscrews must be properly 

installed as described earlier, or fan-wobble could result.

5. 

Install the Clevis Pin, Hairpin Clip and tighten Set 

Screws. (Figure 2)  The Clevis Pin and Hairpin Clip must 
be properly installed to prevent the Set Screws from 
working loose.

6. 

Route wires through Canopy Screw Cover and Canopy.  

Position Canopy on fan shown with open side facing up. 
(Figure 2)

7. 

Reinstall the Hanger Ball (Figure 2) on the Down rod 

as follows.  Route the three 80

˝

 wires through the Hanger 

Ball.  Position the Pin through the two holes in the Down 
rod and align the Hanger Ball so the Pin is captured in the 
groove in the top of the Hanger Ball.  Pull the Hanger Ball 
up tight against the pin. 

Securely tighten the setscrew 

in the Hanger Ball.  A loose setscrew could create fan 
wobble.

8.  

The fan comes with blue, black, and white leads.  Before 

installing fan, measure up approximately 6-9 inches above 
top of Downrod/Hanger Ball Assembly.  Cut off excess wire 
and strip back insulation ½

˝

 from each end of wires.

9. 

You have now completed the assembly of your new 

ceiling fan.  You can now proceed with the hanging and 
the electrical wiring of your fan.

Figure 1

WARNING

It is critical that the clevis screw in the downrod support 

is properly installed and the setscrews and nuts are 

securely tightened.  Failure to verify that the clevis screw, 

nuts, hairpin clip and setscrews are properly installed 

could result in the fan falling.

Downrod/

Hanger Ball 

Assembly

Figure 2

Clevis

Pin

Hairpin

Clip

Ceiling

Canopy

Set Screw (2)

Downrod

Support

Pin

Setscrew

Hanger

Ball

Canopy

Screw Cover

Содержание Edgewood TF100 Series

Страница 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model No TF100 The Edgewood Standard Ceiling Fan Net Weight 7 26 kg 16 lbs...

Страница 2: ...may also have other rights that vary from state to state 10 A certain amount of wobble is normal and should not be considered a problem or a defect LIMITED LIFETIME WARRANTY Extends to the original pu...

Страница 3: ...Canopy One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Four wire connectors supplied WARNING Do not install or use fan if any part is damaged or missing This prod...

Страница 4: ...for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Energy Efficient Use of Ceiling Fans Ceiling fan performance an...

Страница 5: ...anopy Screw Cover and Canopy Position Canopy on fan shown with open side facing up Figure 2 7 Reinstall the Hanger Ball Figure 2 on the Down rod as follows Route the three 80 wires through the Hanger...

Страница 6: ...hung with at least 7 of clearance from floor to blades Figure 1 WARNING The outlet box must be securely anchored Hanger bracket must seat firmly against outlet box If the outlet box is recessed remov...

Страница 7: ...n Wire Ground from Hanger Bracket Green Wire Ground Black Fan Wire White Blue Green Wire Ground from Hanger Bowl Figure 1 WARNING To avoid possible electrical shock be sure electricity is turned off a...

Страница 8: ...ith lock washers securing the Blade Holders to the Motor Hub are tight and that the Blade Holders are properly seated Figure 2 NOTE Periodically check Blade Holder hardware and re secure if necessary...

Страница 9: ...ain Figure 2 Operating Instructions Pull Chain 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the...

Страница 10: ...APGAC110BL 2 Downrod Hanger Ball Assembly Containing ADRAC45 2a Hanger Ball 2b Downrod 2c Clevis Pin 2d Bridge Pin 3 Ceiling Canopy P10040 4 Canopy Screw Cover AP10045 5 Fan Motor Assembly MATF100 6...

Страница 11: ...11 NOTE The illustration shown is not to scale or its actual configuration may vary TF100 Standard Fan Exploded View Figure 1 2a 2b 2c 2d 2 3 4 5 7 1 6 8 9...

Страница 12: ...state controls are not recommended choose an alternative control method 6 Tighten screws securely 3 FAN WOBBLES EXCESSIVELY 1 Setscrew and nut in downrod support is loose 2 Setscrew in downrod hanger...

Страница 13: ......

Страница 14: ...Copyright 2007 Fanimation 2007 02 10983 Bennett Parkway Zionsville IN 46077 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Отзывы: