F&U PAH-1229 Скачать руководство пользователя страница 1

                                                                                                                                                                                                                                             

Page: 1/16                                                                                                                                               

 

 

PAH-1229 Mobile Air Conditioning 

 

 

 

 

 

 

User Manual   

 

Содержание PAH-1229

Страница 1: ...Page 1 16 PAH 1229 Mobile Air Conditioning User Manual ...

Страница 2: ...Page 2 16 Content I Notes 3 II Features and Components 5 III Installation and Adjustment 7 IV Control Setting 9 V Drainage Instructions 13 VI Maintenance 14 VII Troubleshooting 15 VIII Appendix 16 ...

Страница 3: ...ower plug is intact and firmly plugged into the power outlet and place the power cord orderly to prevent someone from being tripped or pulling out the plug Do not put any object into the air inlet and outlet of the air conditioning Keep the air inlet and outlet free from obstructions When drainage pipes are installed ensure that the drainage pipes are properly connected and are not distorted or be...

Страница 4: ...cal solvents such as gasoline and alcohol When you need to clean the air conditioning you must disconnect the power supply and clean it with a half wet soft cloth If the machine is really dirty scrub with a mild detergent The appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities if they have been given supervision or instruct...

Страница 5: ...o facilitate operation The remote control can be placed on the back of the body It adopts a user friendly remote control storage design Handles on both sides adopt dividing point design so that it is easier to carry it and the body design is more humane The structure of wrapping the power cord on the back facilitates users to hang the power cord without hanging it down to the ground and staining a...

Страница 6: ...Page 6 16 2 Components ...

Страница 7: ... into the exhaust port on the rear panel counterclockwise Figure2 Figure2 Figure3 Figure 1 1 2 Install the window sealing plate assembly 1 Half open the window and mount the window sealing plate assembly to the window as shown in Figure 2 and Figure 3 the assembly can be placed in horizontal and vertical direction 2 Pull various components of the window sealing plate assembly open adjust their ope...

Страница 8: ...e 2 The pipe cannot be distorted nor has substantial turning greater than 45 Keep the ventilation of the heat pipe unobstructed Figure5 Figure 6 Important Notice The length of the exhaust hose shall be 280 1 500mm and this length is based on the specifications of the air conditioning Do not use extension tubes or replace it with other different hoses or this may cause a malfunction Exhaust must be...

Страница 9: ...Page 9 16 IV Control Setting I Operating instructions LED Control Panel Operation interface is as follows ...

Страница 10: ... both keys to switch between Celsius and Fahrenheit 5 Fan Speed Selection Key In cooling mode press the key to select high medium or low wind speed operation In fan mode press the key to select high medium or low wind speed operation In heating mode press the key to select high medium and low wind speed operation In dehumidification mode pressing the key is invalid and the fan will forcibly choose...

Страница 11: ...to switch between cooling air supply dehumidification mode 3 Up press the key to increase temperature and timing set value 4 Down press the key to reduce temperature and timing set value 5 Fan press the key to select high medium and low wind speed output circularly 6 Timer press the key to set timing value 7 Swing Press the key to open or close swing style Air flow of the air outlet can blow at di...

Страница 12: ...overheat protection in heating mode During the protection period the compressor and the lower motor will stop operation and will automatically return to normal heating state after the temperature of the machine recovers 3 5 Protection Function of the Compressor To increase the service life of the compressor it has a 3 minute delay booting protection function after the compressor is turned off V Dr...

Страница 13: ...nplug the water plug 2 Set the drainage pipe into the water outlet 3 Connect the drainage pipe to the bucket VI Maintenance Cleaning before cleaning and maintenance turn off the machine and unplug the plug 1 Clean the surface Clean with surface of machine with a wet soft cloth Don t use chemicals such as benzene alcohol gasoline etc otherwise the surface of the air conditioning will be damaged or ...

Страница 14: ...on Storage 1 Unscrew the drainage cover unplug the water plug and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers 2 Turn on the machine adjust it to low wind ventilation mode and maintain this state until the drainage pipe becomes dry so as to keep the inside of the body in a dry state and prevent it from milde...

Страница 15: ...her sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise The air conditioning is not placed on a flat surface Put the air conditioning on a flat and hard place to reduce noise compressor does not work Frost production starts Wait for 3 minutes until the temp...

Страница 16: ...cal community waste collection recycling centre In the European Union there are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product complies with the requirements of below directives EMC Directive 14 30 EU Low Voltage Directive 14 35 EU CE Mark...