Purpose
Electronic bistable pulse relay switch that turns on or off lights or
other equipment from several different points with the parallel
connected momentary (bell) control switches.
The relay has two independently controlled channels.
D141222/150119
Specifications
Wiring diagram
Operation
The relay is activated with a current pulse caused by the press of
any momentary (bell) button connected to the relay. Subsequent
pulse will switch the relay off.
The relay has two independently controlled channels.
Control is carried out by means of two separate signal inputs.
Pulse on S1 input controls the R1 output. S2 input and R2 output
operate on the same basis.
The relay does not have a "memory" of the contact position, i.e.
when power returns after power failure, contact of the relay will
be set in the disabled state. This prevents automatic switching of
controlled receivers without supervision after prolonged power
outage.
BISTABLE RELAY
dual-channel
BIS-416
5
9 0 8 3 1 2
5 9 8 2 7 5
power supply
V AC
contact / AC-1 load current
control L pulse current
< mA
response delay
0.1÷0.2s
power indicator
green LED
power consumption
standby
0.
W
on
0.6W
working temperature
-
÷50°C
terminal
2.5mm screw terminals
tightening torque
0.4Nm
mounting
in the Ø60 flush-mounted box
ingress protection
I 20
100÷265
2×1NO / 2×[<8A]
5
15
25
²
dimensions
Ø
54 (□48×43mm), h=20mm
P
N
N
2
3
5
L
1
S2
L
6
4
PWR
N
L
S1
R2
R2
R1
R1
L
S1
S2
N
R1
R2
Installation
Note!
R1
R2
S1
S2
U
1000W
500W
600W
incandescent
fluoroscent
energy-saving
halogen
LED
250W
120W
Power table
The above data are indicative and will heavily depend on the
design of a specific receiver (that is especially important for LED
bulbs, energy-saving lamps, electronic transformers and pulse
power supply units), switching frequency and operating
conditions.
For more information visit
:
www.fif.com.pl
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: [email protected]
Do not dispose of this device to a garbage bin with other unsorted waste!
In accordance with the Waste Electrical and Electronic Equipment Act
any household electro-waste can be turned in free of charge and in any
quantity to a collection point established for this purpose, as well as to the
store in the event of purchasing new equipment (as per the old for new rule,
regardless of brand). Electro-waste thrown in the garbage bin or abandoned
in the
bosom of nature pose a threat to the environment and human health.
WARRANTY.
The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealeror directly with us. More
information how to make a compliant can
be found on the website:
www.fif.com.pl/reklamacje
1. Disconnect the power supply.
2. Mount relay in the flush-mounted box.
3. Connect the power supply cables to PWR group: phase wire L
to terminal 4, neutral wire N to terminal 3.
4. Parallel connected S1 momentary switches (R1 section
control) connect to terminal 2 and phase wire L. Parallel
connected S2 momentary switches (R2 section control)
connect to terminal 1 and phase wire L.
5. Powered receiver of section R1 connect in series to terminal 6
and neutral wire N. Powered receiver of section R2 connect in
series to terminal 5 and neutral wire N.
BIS-416 is compatible with backlit buttons.