General introduction 

 

 

 

 

 

 

Before installing and commissioning the Aura 70, read the safety instructions, provisions and conditions carefully. 
This paragraph contains a number of general safety instructions. The installation of the device and remedying of 
any malfunctions should be performed by a certified electrical installer according to the applicable norms. The 
guarantee does not apply if this product is installed in any other way than is indicated by Fancom and if the 
product's motor has been opened and changes have been made to the product. 

 

Disconnect power before installation or before carrying out any maintenance to the control computer. 
You must be able to switch off the device using a bipolar main switch. 

 

Take precautions against electrostatic discharge (ESD) when working on the control computer. Ensure 
the workplace is clean and dry.   

 

Use the wiring/cables indicated on the connection diagrams and follow all. Only apply power after the 
wiring has been connected correctly. Incorrect connections can cause permanent damage. Before a 
new fuse is placed, the cause of the defect should be remedied by an authorized installer. Only replace 
a defective fuse by a fuse of the same type (see connection diagram). 

 

Inspect the control computer regularly for any damage. Report any damage to your installer 
immediately. A damaged control computer is dangerous! Do not use running water (high pressure 
cleaners) to clean your control computer. The control computer is water resistant, but not waterproof! 
Do not switch off the computer when houses are unoccupied; otherwise there is the risk of 
condensation in the computer.   

 

The installation, of which this product is a part, must be equipped with a reliable, independent alarm 
system, for example, a minimum/maximum thermostat. We advise you to test the alarm system every 
day for proper functioning. 

 

Connect each Fancom device according to the applicable legislation/regulations of the local energy 
provider. 

 

Check that the mains voltage and frequency, for which this computer is suitable, correspond to the 
mains voltage and frequency on site. 

 

Low-voltage and high-voltage wires may not be placed parallel to each other but may cross each other. 

 

When using metal ducts, Fancom advises grounding the ducts at the ends and at as many other places 
as possible. 

 

Connect the computers to one group, from the main distributor. 

 

Keep signal and power cables as short as possible. 

Содержание AURA 70

Страница 1: ...g...

Страница 2: ...duced by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom concerned In spite of the c...

Страница 3: ...7 4 User settings 8 4 1 Overview 8 4 2 Feeding times 8 4 3 Circuit times 9 4 4 Registration 9 5 Alarm 10 5 1 Alarm overview 10 5 2 Alarm settings 13 5 3 Alarm history 13 6 Installing the Aura 70 14 6...

Страница 4: ...uggestions Note providing recommendations and additional information Warning indicating damage to the product if you do not follow procedures carefully Warning indicating danger to humans or animals E...

Страница 5: ...remedied by an authorized installer Only replace a defective fuse by a fuse of the same type see connection diagram Inspect the control computer regularly for any damage Report any damage to your inst...

Страница 6: ...lling process starts the dispensers will open and the feed will fall into the troughs Filling the dispensers when the filling process starts the dispensers will be filled first The basic components of...

Страница 7: ...combination with dispensers The chain will start first to dose the feed into the dispensers After a settable wait time the silo auger starts to filling the circuit until the feed return sensor detects...

Страница 8: ...ime sections can be inspected and dispensers can be adjusted per animal After the wait time the system starts the circuit filling process The chain will start first to dose the feed into the dispenser...

Страница 9: ...be operated on the touch screen 1 Touch screen 2 Silo 1 control switch 3 Silo 2 control switch 4 Circuit control switch automatically switch off in case of a chain break 5 Dosator control switch The c...

Страница 10: ...ble menus and an alarm indicator to navigate to more details Only data important to you will appear on your control computer This has been set in the installation menus This chapter explains all the m...

Страница 11: ...s used 4 Return feed sensor If the return feed sensor detects feed it will stops the silo auger from filling the circuit 5 System full sensor If the chain is full the symbol light up green and the sys...

Страница 12: ...le Readout of the circuit number Readout of the run time of today Readout of the run time of yesterday Readout of the run time of the day before yesterday Readout of the total run time To reset the va...

Страница 13: ...arm which has been recovered The controller switches off the alarm but the alarm status remains visible Alarm disabled switch off the alarm entirely Only do this when houses are unoccupied Do not forg...

Страница 14: ...thin the set time Check the sensor and adjust the delay setting if necessary Return feed sensor Signal actual time not set Check and adjust time if necessary Power failure Signal when starting up afte...

Страница 15: ...alarm situation 3 Press once more The alarm message will disappear and the alarm status changes into Alarm temp off followed by Alarm stand by If the alarm is disabled the control computer will not g...

Страница 16: ...ra 70 Alarm 13 Max runtime circuit Setting of the maximum runtime hours minutes One setting for all circuits The control computer stores the alarm history The computer stores the last six alarm messag...

Страница 17: ...er pipes drainage pipes etc Never mount the Aura 70 in a humid and or dusty room and certainly not in the room where the animals are present Mount the Aura 70 at such a height that you can control the...

Страница 18: ...of moisture dust and or aggressive gasses Check that the mains voltage and frequency for which this computer is suitable correspond to the mains voltage and frequency on site Be sure that the Aura 70...

Страница 19: ...a dipswitch is used to terminate the control computer Example Setting the terminal resistor FNet Four control computers connected using FNet Control computers 1 and 4 are at the end of the network The...

Страница 20: ...net by several computers activating simultaneously Fancom advises always entering a computer number Computer name Setting of the name of the control computer Temperature unit Setting of the unit of te...

Страница 21: ...mber of transmitted messages Sent counter and readout of the number of received messages Receive counter no PC messages These counters can be used to trace faulty communication connections In this cas...

Страница 22: ...eeding times Setting of the number of feeding times for all circuits maximum 24 Dosator relay Setting of the output address of the dosator NO Rel 2 AO 1 Start with Setting of the start situation Filli...

Страница 23: ...ern alarm 2 and Extern alarm 3 are free to use Extern alarm input 1 2 3 Setting of the input address of the external alarm NO DI NC DI NO Overview of the relays analog inputs analog output and digital...

Страница 24: ...limate Operating temperature range 0 C to 40 C Storage temperature range 10 C to 50 C Relative humidity 95 uncondensed Aura 70 I O board 7 analog inputs Used as digital input Status high is R 150 Stat...

Страница 25: ...Aura 70 Technical specifications Aura 70 Switchbox 22 1 Aura board 2 Powerboard FCA 1 Silo switch 1 2 Silo switch 2 3 Chain switch with softstarter optional...

Страница 26: ...23 1 IO Net 2 IO Net 3 Fnet 1 4 Fnet 1 5 Fnet 2 6 Fnet 2 7 SD Card 1 AI1 System full sensor 2 AI2 Dosator close input external start 3 AI3 Return feed sensor 4 AI4 Silo switch over sensor 5 AI5 Exter...

Страница 27: ...ver NC 5 Dosator motor 240V N 6 Dosator motor 240V Open 7 Dosator motor 240V Close N Power supply L1 Power supply L2 Power supply L3 Power supply US variant 1 2 Chain break NC 3 4 Chain drive safety s...

Страница 28: ...Switchbox 25 Standard L1 L2 L3 1 Silo 1 auger motor 2 Silo 2 auger motor 3 Chain drive motor or chain drive motor with softstarter US Variant 1 Silo 1 auger motor 2 Silo 2 auger motor 3 Chain drive mo...

Страница 29: ...lace Panningen the Netherlands Hereby declares that Aura 70 Satisfies the conditions of 1 The Low Voltage Directive 2014 35 EU according to EN 61010 2 the EMC Guideline directive 2014 30 EU Emission a...