Aura 37
Installer settings
24
Influence maximum ventilation limitation during cooling
Limit maximum
ventilation
Setting if the cooling must influence the maximum ventilation limit (
YES
/
NO
).
Max ventilation during
cooling (%)
Setting of the maximum ventilation percentage during cooling (0 to 100%).
Influence stop (evaporative) cooling above relative humidity percentage
Stop above RH%
Setting if the control computer must deactivate the evaporative cooling if the relative
humidity becomes too high (
YES
/
NO
).
Stop evap cooling above
RH (%)
Setting of the relative humidity percentage above which the evaporative cooling stops
(0 to 100%).
Temperature sensor 1 / temperature sensor 2 / temperature sensor outside
Input type
Setting indicating the analog control type (
NONE
/
SENSOR
/
EXTERNAL
*).
* External only used for temperature sensor outside.
Input number (analog)
Readout of the sensor input number.
Correction
Setting of the difference (offset) in the measured temperature compared to the actual
temperature from the sensor.
RH Sensor
Input type
Setting indicating the analog control type (
NONE
/
SENSOR
).
Input number (analog)
Readout of the sensor input number.
Correction
Setting of the difference (offset) in the measured relative humidity compared to the
actual relative humidity from the sensor.
Содержание AURA 37
Страница 1: ...g ...
Страница 31: ...Aura 37 Appendix Connection diagram Aura 37 28 ...
Страница 32: ...Aura 37 Appendix Connection diagram for alarm 29 ...
Страница 34: ...Aura 37 Technical specifications 31 1 Aura board 2 Powerboard FC REL13 1 Powerboard RC REL13 ...
Страница 35: ...Aura 37 Technical specifications 32 1 IO Net 2 IO Net 3 Fnet 1 4 Fnet 1 5 Fnet 2 6 Fnet 2 7 SD Card ...