Lumina 750
Classic screens
End value
Setting of the compost/tunnel end temperature (°C/°F). The compost/tunnel
temperature control value will gradually approach this end value.
Adjustment/h
Setting of the adjustment speed of the
Compost temperature control value
(°C/hour
or °F/hour).
Ct1 - Ct8
Readout of the measured compost temperatures of the individual sensors. A
negative value indicates that this sensor is not included in the calculation of
the average compost temperature (opposite value to the current measured
temperature). The value -9.9 or +99.9°C(14°F or 212°F) indicates that the sensor
concerned is either faulty or not connected.
Tt1 - Tt2
Readout of the measured tunnel temperatures of the individual tunnel sensors. The
value # indicates that the sensor concerned is either faulty or not connected.
Deviation Ct.
Setting of the maximum number of degrees a compost sensor may differ from the
previous average compost temperature, if it is to be included in the calculation of
the new average. The value 0 means that only non-faulty sensors are included in
the calculation.
Deviation Tt.
Setting of the maximum number of degrees a compost sensor may differ from the
previous average tunnel temperature, if it is to be included in the calculation of the
new average. The value 0 means that only non-faulty sensors are included in the
calculation.
Control
Setting of the type of compost/tunnel temperature control:
●
COMPOST
: The compost/tunnel temperature control is based on the average
compost temperature.
●
TUNNEL
: The compost/tunnel temperature control is based on the average
tunnel temperature.
●
COMP+TUN
: The compost/tunnel temperature control is based on the average
of compost and tunnel temperature.
6.4
Function key 3: Air inlet temperature
3
Ctr.
Readout of the current air inlet temperature control value. Each time a phase is
started the Lumina 750 will make the control value equal to the measured air inlet
temperature. The Lumina 750 calculates the air inlet temperature control value
depending on the average compost/tunnel temperature.
Meas
Readout of the measured or average air inlet temperature (°C/°F).
38