Chapter 5 Operation Instructions
Shenzhen Hpmont Technology Co., Ltd.
- 36 -
MONT72 Series User Manual V1.0
5.1.2
Controller Status
Controller status Description
Stop status
After MONT72 is switched on and initialized, if no run command inputs or the stop command is
given, there will be no output from U / V / W of MONT72.
Run status
The controller will start output from U / V / W terminals after it receives the run command.
And the LCD keypad will display / (motor reversed rotation/ positive rotation).
Motor
parameters
auto-tuning
Set F07.06 / F10.10 = 1 or 2, MONT72 will receive the run command then enter motor
parameters auto-tuning status. If the auto-tuning process is completed, the controller will enter
into stop status.
Fault alarm status MONT72 has fault.
Under-voltage
status
MONT72 is under-voltage.
5.1.3
Control Mode
MONT72 series have three control modes which are V/f control, SVC control and VC control. (Refer to
F00.01 for more detail)
5.1.4
Controller Running Mode
Running mode
Description
Auto-tuning
running
Set F07.06 / F10.10 = 1 or 2 and press
key to enter the auto-tuning running.
MS speed
running
The run speed is set by MS1 - MS3 in combination or communication.
•
This mode is accessible when F00.05 = 2.
Inspection
running
When inspection signal is valid, the speed will be set by F05.08 (Inspection run speed).
This mode is accessible when F00.05 = 1, 2.
Battery-driven
running
When emergency signal is valid, the speed will be set by F05.09 (Battery driven run speed).
This mode is accessible when F00.05 = 1, 2.
Normal running
Controlled by keypad (F00.05 = 0) or terminal analogue (F00.05 = 1).
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......