Chapter 4 Electrical Installation
Shenzhen Hpmont Technology Co., Ltd.
- 20 -
MONT72 Series User Manual V1.0
4.4
Control Board
•
The control circuit is designed as an ELV (Extra Low Voltage) circuit, which is basically insulated from the power
circuit. The drive controller cannot be touched after power-on.
•
If the control circuit is connected to an external device with a port that is accessible during power-up (SELV
circuit), be sure to add a level of additional insulation protection isolation to ensure that the original SELV voltage
level of the external device is not changed.
•
It is forbidden to connect the control terminal other than the relay terminal to the AC 220V voltage signal.
Figure 4-1 MCB terminals
4.4.1
Indicators and Jumper Description
Table 4-6 Indicators and jumper description
Indicators and jumper
Description
RUN indicator
(Green)
Normal, always on; Running, flashing period 0.6s.
J1 jumper
Digital input terminals X1 - X10 are high / low level selection:
When 1,2pin is shorted, it is active low (factory setting);
When 2,3pin is shorted, it is active high.
Danger
Warning
Y1 CM1 Y2 CM2 Y3 CM3 RA RB RC DO2 CME COM
X1
X2
X3
X4
X5
X6
X7
X8
X9
X10
+24V
DO1
AI1
COM
+10V
GND
SK2
SK1
Encoder card interface
MCB
J1
RUN
SK1
SK2
CN12
3
1
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......