Attach the extension supporting elements (
sP
) to the trellis (
t1
) using the 8 self-threading screws (
v4
) through the pre-drilled holes (Fig.
1
)
•
Mark 4 drilling points on the ceiling (also identiied on page
3
), drill (Fig.
2
) Put in 4 x ø 8mm expansion bolts and secure the extension
supporting elements (
sP
) to the ceiling by the relative screws (
v1
) (Fig.
3
).
With false ceilings, the extension supporting elements (SP) must always be bolted to the false ceiling: said false ceiling must be reinforced
or somehow itted with a solution that can guarantee safely attaching the hood to it, taking into account the strength of the used materi-
als and the weight of the hood (reported on page.
2
).
the ixing kit (screws and plugs) supplied with the hood can only be used on masonry walls:
should it be necessary to install the
hood onto walls in a diferent material, assess other ixing systems keeping the wall resistance and weight of the hood in mind (indicated
on page
2
).
eXterNAL eXhAust hooD versioN (suctioN)
•
If you wish, install the check valve (
m
)(
Phase
D
page 5
); if the connection is installed (
erm
) take it down (Fig.
1
), install the check valve (
m
)
as illustrated in the igures (Fig.
2
-
3
-
4
-
5
) and put the previously removed connection back in (
erm
) (Fig.
6
).
•
Find the best length for the lexible (recommended) or rigid pipe to discharge the fumes and connect it suitably to the connection (
Phase
e
page 5
).
hooD versioN With iNterNAL recircuLAtioN (fiLteriNg)
•
Ensure that the active carbon ilters are assembled onto the hood, if not, install them as indicated in the instructions
P
on page
9
.
•
If installed, remove the connection (
erm
) and any check valve (
m
) installed on the hood's air outlet itting (perform, in reverse order, the opera-
tion described in the instructions
D
page 5
).
iNstALLAtioN oN ceiLiNg
Phases
f
-
g1
-
h
-
i
-
L
iNstALLAtioN oN ceiLiNg With fALse ceiLiNg
Phases
f
-
g2
-
h
-
i
-
L
iNstALLAtioN oN ceiLiNg Without eXteNsioN (h) AND treLLis (t)
Phases
m
-
N
Phase
f
page 6
•
Insert the extension (
h
) into the lue (
g
) and secure them together with masking tape.
•
With external exhaust (suction) versions, it is possible to insert extension (
h
) with the slots facing downwards so that they are not visible when
the installation height allows it.
Phase
g1
page 6 (only for installations on ceiling Without false ceiling)
•
Raise the assembly (
h+g
) until it is touching the ceiling (Fig.
1
).
•
Attach the assembly (
h+g
) to the trellis (
t
) with 4 screws (
v3
) without tightening them all the way (Fig.
2
).
Phase
g2
page 6 (only for installations on ceiling With false ceiling)
Attach the extension supporting elements (
sP
) to the trellis (
t
) with 8 self-threading screws (
v4
) being sure to press it up against the false ceiling
Fig.
1
).
•
Raise the assembly (
h+g
) until it is touching the false ceiling (Fig.
2
).
•
Attach the assembly (
h+g
) to the extension supporting elements (
sP
) with 4 screws (
v3
) without tightening them all the way (Fig.
3
).
Phase
h
page 7
•
Raise the hood so that it is near the trellis that is already attached to the ceiling (Fig.
1
).
•
Centre the 4 metric screws, (
v5
) that are pre-screwed onto the trellis, (
t1
) (Fig.
2A
) on the holes on the hood; shift the hood sideways and tighten
the 4 metric screws deinitively (
v5
) (Fig.
2B
).
Phase
i
page 7
•
Remove the masking tape that was temporarily holding the lue (
g
) and extension (
h
) (Fig.
1
)
•
Take out the 4 screws (
v3
) that attach the extension (
h
) to the trellis (
t
) (Fig.
2A
) or, with false ceilings, to the extension supporting elements (
sP
)
(Fig.
2B
) and slide the extension (
h
) downwards (Fig.
3
). Keep the removed (
v3
) screws.
•
By lowering the extension (
h
) it is possible to connect the pipe (
f
) to the external discharge pipe (with the suction version)(Fig.
4
).
•
Set up the electric connection only once the electric power supply has been cut of.
Phase
L
page 7
•
When the electrical connection is set up, as well as the discharge connection, raise the extension (
h
) (Fig.
1
) and re-attach it to the trellis (
t
) (Fig.
2A
) or, with false ceilings, to the extension supporting elements (
sP
) (Fig.
2B
) by the 4 screws (
v3
).
•
Attach the lue (
g
) to the hood by 2 self-threading screws (
v6
) (Fig.
3
).
iNstALLAtioN oN ceiLiNg Without eXteNsioN (h) AND treLLis (t)
Phase
m
page 8
•
Attach the lue (
g
) to the hood by 2 self-threading screws (
v6
) (Fig.
1
).
Phase
N
page 8
•
Raise the hood towards the trellis (Fig.
1
).
•
Set up the connection with the external discharge pipe and the electrical connection, performing the latter after disconnecting the electrical
power supply.
•
Centre the 4 metric screws, (
v5
) that are pre-screwed onto the trellis, (
t1
) (Fig.
2A
) on the holes on the hood; shift the hood sideways and tighten
the 4 metric screws deinitively (
v5
) (Fig.
2B
).
Содержание luce
Страница 2: ...2 46 600 max 572 320 318 255 121 258 max 1218 898 596 8 mm Luce isoLA 32 kg 800 m3 h...
Страница 9: ...9 itALiANo 3 1 2 2 2 1 O P 3 4 M V3 x3 1 N 2 Q...
Страница 47: ...47 2 13 il l 8...
Страница 48: ...48 1 5 47 A 4 65 25 6 EN60335 2 31 11 07 2002 TC61 7 12 1 15 10 11 70 C III...
Страница 51: ...51 15 30 3 4 53 1 1 3 24 24h 3 3 15 1 30 3 o 9 24h 1 1 1 1 3 24 1 1 3 24 24 3...
Страница 52: ...52 2 2 1 1 2 2 3 3 1 1 3 3 4 4 1 1 4 4 4 7 3 Q 9 N 1 2 3 4 3 4 N 1 2...
Страница 53: ...53 15 Magic Steel 1 55 C o 9 3 4 o 9 P 9 e c WEEE...