If the equipment is sold or transferred to another per-

son, make sure that the booklet is also supplied so 

that the new user can be made aware of the hood's 

operation and relative warnings. 
After the stainless steel hood has been installed, it 

will need to be cleaned to remove any residues re-

maining from the protection adhesive as well as any 

grease and oil stains which, if not removed, can cause 

irreversible damage to the hood surface. To properly 

clean the unit, the manufacturer recommends using 

the supplied moist wipes, which are also available 

sold separately. 
Insist on original spare parts.

INTENDED USE

The equipment is solely intended to be used to 

extract fumes generated from cooking food in 

non-professional domestic kitchens: any other 

use is improper. Improper use can cause damage 

to persons, things, pets and exempts the Manu-

facturer from any liability.

The equipment can be used by children over the age 

of 8 and by persons with reduced physical, sensory 

and mental abilities, or with no experience or knowl-

edge, as long as they do so under supervision or after 

having received relative instructions regarding safe 

use of the equipment and understanding of the dan-

gers connected to it.

Children are not to play with the equipment. Clean-

ing and maintenance by the user must not be carried 

out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching 

off the main switch.

Do not use the hood with wet hands or bare feet.
Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 
The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

3 lb 5 oz (1.5 Kg).
Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.
Do not leave open, unattended flames under the 

hood.
Do not prepare food over an open flame under the 

hood.
Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.

Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.
Do not carry out any cleaning operations when parts 

of the hood are still hot.
There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.
Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room 

where the fumes are discharged is well-ventilat-

ed, in compliance with the local regulations.

  INSTALLATION

   only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SAFETY 

INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-

ment and the lowest part of the hood is indicated in the installation in-

structions. 

Generally, when the hood is placed over gas cookers, the distance must be 
at least 65 cm (25.6''). However, according to an interpretation of standard 
EN60335-2-31 dated 11-07-2002 of TC61 (sub-clause 7.12.1 meeting 15 agenda 
item 10.11), the minimum distance between the cooker and lower part of the 
hood can be reduced to the quota reported in the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be-

fore carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions of law 

in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the techni-

cal specifications located inside the hood);

•  the power supply plug and cable do not come into contact with tempera-

tures exceeding 158 °F (70 °C);

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.

In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to 
an adequate safety socket.

Содержание FFPLN36I5FS

Страница 1: ...EN INSTRUCTIONS BOOKLET FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES IT LIBRETTO ISTRUZIONI Plane island FFPLN36I5FS...

Страница 2: ...2 1 2 318 mm 10 1 8 258 mm 10 1 8 258 mm max 48 7 8 1242 mm 4 3 4 121 mm 35 3 8 898 mm 21 5 8 550 mm 68 lb 31 kg Plane Island 36 Cod FFPLN36I5FS 120VAC 60Hz 280W 5 16 8 mm 1 4 6 mm EN tool required FR...

Страница 3: ...265 mm EN cable length 5 0ft 1 5m FR longueur de c ble 5 0ft 1 5m ES longueur de c ble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m Side outlet which can only be used with false ceiling Sortie lat rale uti...

Страница 4: ...rer le rail sup rieur du rail inf rieur 1 Retrait des filtres 2 3 ES Operaciones preliminares separar la estructura superior de la estructura inferior 1 Extracci n de filtros 2 3 IT Operazioni prelimi...

Страница 5: ...onaux et locaux qui remplacent toutes les recommandations stipul es dans le pr sent document ES Medidas instalaci n La altura de montaje recomendada desde la superficie de cocci n hasta el fondo de la...

Страница 6: ...e 6 FR Installation au plafond sans extension de chemin e et sans rail de ixation sup rieure 6 ES Instalaci n en el techo sin extensi n de chimenea y poste superior 6 IT Installazione a soffitto senza...

Страница 7: ...7 5 16 8mm x4 4 3 1 2 2 x8 1 H1 EN Trestle 7 and extension 8 assembly FR Montage support de fixation 7 et rallonge 8 ES Montaje estructura 7 y prolongaci n 8 IT Montaggio traliccio 7 e prolunga 8 7 8...

Страница 8: ...hout upper trestle and without extension 9 FR Installation sur plafond sans support de fixation sup rieur et sans rallonge 9 ES Instalaci n en techo sin estructura superior y sin prolongaci n 9 IT Ins...

Страница 9: ...R Montage clapet anti retour 10 tube d aspiration 11 assemblage conduit d vacuation 12 ES Montaje de v lvula de no retorno 10 tubo de aspiraci n 11 montaje de chimenea 12 IT Montaggio valvola di non r...

Страница 10: ...N G C O N T R O S O F F I T T O 3 V3 x4 13 14 15 EN Ceiling configuration 13 False ceiling configuration 14 15 FR Installation sur plafond 13 Installation sur faux plafond 14 15 ES Configuraci n en t...

Страница 11: ...et fixation conduit d vacuation rallonge 17 ES Instalaci n c mara motor 16 conexi n el ctrica y fijaci n de chimenea prolongaci n 17 IT Installazione camera motore 16 collegamento elettrico e fissagg...

Страница 12: ...nstallation au plafond sans rallonge H ni treillis T 18 19 ES Instalaci n en techo sin extensi n H y enrejado T 18 19 IT Installazione su soffitto senza prolunga H e traliccio T 18 19 EN Mandatory saf...

Страница 13: ...neau 20 enlever les filtres m talliques 21 Montage du filtre en option 22 ES Procedimiento de desmontaje quite el panel 20 quite los filtros met licos 21 Montaje del filtro opcional 22 IT Procedura di...

Страница 14: ...ements rain wind etc ELECTRICAL SAFETY The electrical system to which the hood is to be connected must be in accordance with local standards and supplied with earthed connection in compliance with saf...

Страница 15: ...instructions and products indicated in this booklet Disconnect the main switch when the equipment is not used for long periods of time If other appliances that use gas or other fu els are being used...

Страница 16: ...in the assembly instruc tions In this version the check valve must not be assembled remove it if it is on the air outlet fitting of the motor ASSEMBLY INSTRUCTIONS only intended for personnel qualifie...

Страница 17: ...nto the environment The active carbon filters must be replaced on average every 3 4 months under normal conditions of use See assembly instructions to replace the active carbon filters LIGHTING The ra...

Страница 18: ...t de tenue m canique Ne pas installer la hotte l ext rieur et ne pas l expo ser des agents atmosph riques pluie vent etc S CURIT LECTRIQUE Le circuit lectrique auquel est reli e la hotte doit tre aux...

Страница 19: ...pas allumer de flammes nues sous la hotte Ne pas cuisiner avec une flamme nue sous la hotte Ne jamais utiliser la hotte sans les filtres m talliques anti graisse dans ce cas la graisse et la salet se...

Страница 20: ...ine et des appareils aliment s avec une nergie diff rente de l nergie lectrique sont en fonction simultan ment la pression n gative dans la pi ce ne doit pas d passer 4 Pa 4 x 10 5 bars HOTTE RECIRCUL...

Страница 21: ...L air pur est ainsi renvoy dans la pi ce Les filtres au charbon actif doivent tre remplac s en moyenne tous les 3 4 mois dans des conditions d utilisation normales Pour le remplacement des filtres au...

Страница 22: ...tmosf ricos lluvia viento etc SEGURIDAD EL CTRICA La instalaci n el ctrica a la cual se conecta la campana debe respetar las normas co rrespondientes y tener obligatoriamente una conexi n a tierra seg...

Страница 23: ...calientes Si no se realiza la limpieza seg n las modalidades y los productos indicados en este manual esto puede conllevar un riesgo de incendio Desconecte el interruptor general si no va a usar el eq...

Страница 24: ...biente Controle que los filtros de carb n activo est n montados en la campana si no es as m ntelos tal como se indica en las instrucciones de montaje En esta versi n la v lvula de no retorno no debe e...

Страница 25: ...ben ser sustituidos cada 3 4 meses en condiciones de uso normal Para sustituir los filtro de carb n activo consulte las instrucciones de montaje ILUMINACI N La campana cuenta con iluminaci n mediante...

Страница 26: ...conforme alle normative Europee sull antidi sturbo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quella riportata dalla targhetta posta all interno della cappa L...

Страница 27: ...hio di incendio Disinserire l interruttore generale quando l appa recchio non viene utilizzato per periodi prolungati di tempo In caso di utilizzo contemporaneo di altre utenze caldaie stufe caminetti...

Страница 28: ...averso i filtri al carbone attivo per essere purificata e riciclata nell ambiente Controllare che i filtri al carbone attivo siano montati sulla cap pa in caso negativo applicarli come indicato nelle...

Страница 29: ...mbolo del cestino barrato riportato sull apparecchiatura in suo pos sesso indica che il prodotto un RAEE cio un Rifiuto derivante dal le Apparecchiature Elettriche ed Elettroniche e pertanto non deve...

Страница 30: ...30 NOTE NOTES...

Страница 31: ...31 NOTE NOTES...

Страница 32: ...Code 110033060 Ed 01 2020 FALMEC S p A 31029 VITTORIO VENETO Treviso ITALY Zona Industriale Via dell Artigianato 42 www falmec com Codice Code Matricola Serial Number...

Отзывы: