FALCON ELECTRIC, INC.

NEW PRODUCT LIMITED WARRANTY

Limited Warranty:

Falcon warrants that this product will be free from defects in materials

and workmanship for a period of two years from the date of shipment by Falcon.

Procedures:

Any defective product must be returned to Falcon.  No product can be returned 

without first obtaining a Return Material Authorization (RMA) number from Falcon.  Falcon will
repair, replace or refund the purchaser price, at Falcon’s sole discretion, for any defective
product that is returned to Falcon with an RMA number.  For defective product returned within
30 days of shipment, Falcon will pay for shipping costs to and from its service center.  For
defective product returned after 30 days but within 90 days of shipment, Falcon will only pay
for shipping costs in sending the new or repaired product back to the end-user.  For defective
product returned more than 90 days after shipment, all shipping costs will be borne by the
end-user.

Exclusions:

This limited warranty does not cover damage caused by: (i) improper 

installation, misuse or neglect; (ii) unauthorized repairs or modifications or use of unauthorized
parts; (iii) acts or events outside of Falcon’s control, such as fire, accidents, impacts; (iv) 
normal wear and tear, such as cleaning and replacement of batteries. The warranty is null and
void if: (i) the product is used in conjunction with life support equipment; (ii) the factory seal is
broken or shows signs of tampering; or (iii)  the battery is allowed to discharge below the 
minimum battery cutoff point.  To prevent this discharge, remove the battery fuse, or switch
the battery disconnect to the “off” position when the unit is to be stored without the AC power
being supplied to the UPS for more than two days.  The battery must be recharged every four
to six months when not in use.  This limited warranty is not transferable.

Limitations: IN NO EVENT IS FALCON RESPONSIBLE FOR ANY SPECIAL, INDIRECT, 
SECONDARY OR CONSEQUENTIAL DAMAGES, SUCH AS PERSONAL INJURY, 
DAMAGE TO PROPERTY, LOSS OF DATA, LOST PROFITS, ETC.  IN NO EVENT WILL
FALCON’S LIABILITY UNDER THIS LIMITED WARRANTY EXCEED THE PURCHASE
PRICE PAID FOR THE PRODUCT IN QUESTION.

Disclaimers:

The limited warranties set forth in this document are the only warranties that

apply to Falcon’s products.  

ALL OTHER WARRANTIES ARE EXPRESSLY DISCLAIMED,

INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.  THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE.

2007-04 Rev. C 

22

Содержание SG800-1T

Страница 1: ...format at www falconups com FALCON Electric Inc 5116 Azusa Canyon Rd Irwindale California 91706 626 962 7770 Fax 626 962 7720 Email sales falconups com 2011 Falcon Electric Inc All rights reserved Al...

Страница 2: ...udible Alarms 11 Category One Alarms 11 Category Two Alarms 11 Chapter 4 Rear Panel Details 12 SG800 1T SG1K 1T Rear Panel 12 SG800 2T SG1K 2T Rear Panel 12 SG1 5K 1T SG2K 1T SG3K 1T Rear Panel 13 SG1...

Страница 3: ...Voltage Regulation Superior Brownout Surge and Transient Protection Internal System Bypass Eliminates Generator Frequency Voltage Drift Microprocessor Control RS 232 Communications UPSILON Monitoring...

Страница 4: ...ons Keep unauthorized personnel away from batteries When replacing the UPS batteries use the same number and type of batteries Allow at least 24 hours after the UPS is first installed and turned on to...

Страница 5: ...ilding friendly UPS Microprocessor Control Falcon Electric s SG Series UPS incorporates advanced microprocessor technology This technology makes possible a high level of internal UPS control and manag...

Страница 6: ...or 30 seconds the UPS is automatically placed into bypass and the inverter is turned off NO BATTERY BACKUP IS PROVIDED AFTER THE GREEN MODE HAS ACTIVATED Dip switch settings must be made while the UPS...

Страница 7: ...ected has adequate ventilation to allow for the proper cooling of the UPS DO NOT BLOCK UPS FANS OR AIR VENTS THE UPS MUST NOT BE INSTALLED IN AN ENCLOSED AREA 10 Plug the UPS power cord into the neare...

Страница 8: ...SWITCH SETTINGS FOR 1 MODELS SWITCH SETTINGS FOR 2 MODELS GREEN MODE SWITCH SETTINGS FOR ALL MODELS VIEW OF DIP SWITCHES LOCATED ON THE UPS REAR PANEL 6...

Страница 9: ...y charger option installed from the factory perform the following a Verify the battery charger circuit breaker is in the off down position b On the battery bank nameplate label located on the rear pan...

Страница 10: ...BANK SELECTION GUIDE FOR 800VA 1KVA MODELS FOR 1 5KVA 2KVA MODELS FOR 3KVA MODELS 8 NOTE The backup times stated are for reference only Backup time may vary due to the type of load battery age or con...

Страница 11: ...s let when the battery level is above the low battery warning level The first LED is lit when the battery level is above the battery cutoff voltage 3 LINE SITE WIRING FAULT INDICATOR LED For models co...

Страница 12: ...The following describes the different modes of operation for this button a Depressing this button when the UPS is off and the utility voltage is not present or with the UPS input circuit breaker in th...

Страница 13: ...PANEL TEST BUTTON DEPRESSED 2 Category two alarms a Three short beeps indicate the SG UPS output voltage is out of proper operating range SG UPS OUTPUT VOLTAGE IS OUT OF PROPER RANGE b Four short beep...

Страница 14: ...T SG1K 2T Typical Rear Panel Overview 12 CHAPTER 4 CHAPTER 4 REAR PANEL DETAILS Please verify the UPS output rat ings match your requirement COVER PLATE FOR OPTIONAL COMMUNICATIONS INTERFACE BAORD COV...

Страница 15: ...al Rear Panel Overview 13 SG1 5K 2T SG2K 2T SG3K 2T Typical Rear Panel Overview OUTPUT RECEPTACLES Shown with 1 L6 20R 2 6 20T Receptacles COOLING FANS DO NOT BLOCK OUTPUT RECEPTACLES 6 NEMA 5 15R STA...

Страница 16: ...e connected to opposing 120Vac phases SG2K 2TX SG3K 2TX SG2K 1TX SG3K 1TX Output Configurations The SG 2TX models provide galvanic isolation only on the 120Vac outlets The 120Vac outlets have been lim...

Страница 17: ...ed with the UPS There are communications options that WILL DISABLE the RS 232 port and render it inoperable The options are as follows a Internal SNMP HTTP agent option installed into the UPS communic...

Страница 18: ...TERFACE BOARD OPTIONS Typical Falcon Dry Contact Relay Board PIN JUMPER ASSIGNMENT FOR THE FALCON UA88374 RELAY OPTION BOARD no on bypass signal PIN JUMPER ASSIGNMENT FOR THE FALCON UA88376 RELAY OPTI...

Страница 19: ...17 PIN ASSIGNMENT FOR THE FALCON UA88373 OPTO COUPLER OPTION BOARD no bypass signal Typical Falcon Opto coupler Interface Card OPTO Board Internal Circuitry...

Страница 20: ...APC Style Dry Contact Relay Board PIN JUMPER ASSIGNMENT FOR THE FALCON UA88377 RELAY OPTION BOARD APC Style Board 18...

Страница 21: ...Falcon Service Department see page 21 for contact information Never attempt to service batteries High voltage exists within the unit which could cause electrical shock Servicing of batteries should b...

Страница 22: ...he manufacturer s instructions may cause interference to radio and television reception All models covered in this manual have been tested and found to comply with the limits for a Class A computing d...

Страница 23: ...n The original shipping container must be used when returning any SG Series product Falcon Electric will not assume any responsibility for shipping damage In the event of shipping damage you will be n...

Страница 24: ...of Falcon s control such as fire accidents impacts iv normal wear and tear such as cleaning and replacement of batteries The warranty is null and void if i the product is used in conjunction with life...

Страница 25: ...SG SeriesTM UPS PLUS 800VA to 1 5kVA 23...

Страница 26: ...SG SeriesTM UPS PLUS 1TX 1TXI 2kVA 3kVA 24...

Страница 27: ...SG SeriesTM UPS PLUS 2kVA 3kVA 25...

Отзывы: