36
11. Technical Data
This cooker is designed for use on natural gas but can be converted to LP (Propane X (2.54kPa).
A conversion kit from Natural Gas to Propane is supplied with the cooker.
Installer:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Inside base drawer of cavity and on rear of the appliance.
COUNTRY OF DESTINATION:
Australia
Connections
Gas
Rp½ at right rear
Electric
Natural Gas
1kPa
240V 50Hz
Propane
2.54kPa
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 904mm
maximum 931mm
Overall width
900mm; see
‘Positioning of Cooker’
.
Overall depth
65
0mm
Minimum
clearance above
cooktop
800mm
Ratings
Oven
Full
Divided
Fan element
3.31 kW
1.65 kW
Top element
3.49 kW
1.75 kW
Browning element
2.11 kW
1.06 kW
Bottom element
1.38 kW
0.69 kW
Natural Gas 1kPa
Propane 2.54kPa
Hotplate
Input
Injector
Bypass
marking
Input
Injector
Bypass
marking
Marking
Size Ø
Marking
Size Ø
Wok burner
15.2Mjh
-1
Internal 112
1.12mm
90
15Mjh
-1
Internal 66
0.67mm
54
External 164
1.65mm
External 91
0.87mm
Large burner
12.3Mjh
-1
165
1.65mm
80
12Mjh
-1
89
0.96mm
41
Medium burners
6.2Mjh
-1
115
1.15mm
56
6.2Mjh
-1
67
0.68mm
33
Small burner
3.7Mjh
-1
92
0.92mm
48
3.3Mjh
-1
48
0.50mm
25
Maximum total electric load 240V = 3.6kW (including oven fans, lights, etc.)