T100472 Ref. 5

G1808X, G1838X, G1848X

DEEP FAT FRYERS

INSTALLATION and

SERVICING INSTRUCTIONS

These appliances must only be installed, serviced and converted for use with other gases by a

competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and

National Regulations in force at the time of installation. Particular attention MUST be paid to -

Gas Safety (Installation & Use) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act

These units have been CE-marked on the basis of compliance with the Gas Appliance Directive, Gas Types

and Pressures as stated on the Data Plate.

WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER

GAS OR ELECTRIC, MUST BE EARTHED

On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference

during servicing. Further to this, The Users Instructions should be handed over to the User, having had a

demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND

COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY

RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be

arranged with AFE SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and

repairs. A quotation will be given upon request to the contact numbers below.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT -
PHONE - 01438 363 000

FAX - 01438 369 900

Detailed recommendations are contained in

Institute of Gas Engineers published

documents :
IGE/ UP/ 1, IGE/ UP/ 2, BS6173 and BS5440

Содержание G1808X

Страница 1: ...allation these instructions should be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstratio...

Страница 2: ...action system Placing the unit below a ventilated canopy is the most suitable arrangement 1 4 GAS SUPPLY The incoming service must be of sufficient size to supply full rate gas without excessive press...

Страница 3: ...r from the front or from the side 2 3 CONNECTION TO A GAS SUPPLY The unit is supplied with the following fittings G1808X Rp1 2 1 2 BSP G1838X and G1848X Rp3 4 3 4 BSP Gas supply piping and appliance c...

Страница 4: ...mpression nut and remove pipe from pilot burner Withdraw injector Undo thermocouple retaining nut and remove thermocouple from pilot burner Undo thermopile retaining nut and withdraw thermopile Pull H...

Страница 5: ...n This would change the setting Steady spindle and rotate calibration screw clockwise to decrease and anti clockwise to increase temperature The approximate effect of a quarter turn is 27o C Replace c...

Страница 6: ...circuit TEST A COMPLETE MILLIVOLT SYSTEM CHECK a If reading is above 100mV and automatic valve still does not respond replace automatic valve operator b If closed circuit reading A is below 100mV det...

Страница 7: ...Gas Feed Pipe assembled by installers Description No Off Pipe 1 2 2 Union elbow 1 2 male to 1 2 female 2 Tee 1 2 x 1 2 x 3 4 1 300mm 1 2 1 2 1 2 1 2 3 4 1 2 1 2 Gas Supply Pipe Assembly...

Отзывы: