background image

E401F/E402F FRYERS

INSTALLATION, SERVICING 
and USER INSTRUCTIONS

IMPORTANT

The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. 

Particular attention MUST be paid to -

BS7671 IEE Wiring Regulations

Electricity at Work Regulations

Health And Safety At Work Act

Fire Precautions Act

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC
directives for the voltages stated on the data plate.

WARNING -THIS APPLIANCE MUST BE EARTHED

On completion of the installation these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT

In order to obtain maximum performance from this unit we would recommend that a Maintenance
Contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the SERVICELINE contact
numbers below.

WEEE Directive Registration No. WEE/DC0059TT/PRO

At end of unit life, dispose of appliance and any replacement parts in a safe manner, via
a licenced waste handler. Units are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

SERVICELINE CONTACT

Phone: 01438 363 000

Fax: 01438 369 900

T100738 Ref. 6

Содержание E401F

Страница 1: ...tion and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be arranged with SERV...

Страница 2: ...on systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems ...

Страница 3: ... a firm level floor in a well lit draught free position The fryer should be installed in a freestanding position to prevent any possibility of sideways tipping under force The means of restraint may be the manner of installation such as connection to a battery of appliances or installing the fryer in an alcove or by separate means such as adequate ties 1 2 1 Anti tipping Bracket An anti tipping me...

Страница 4: ...eating of solid fats 3 Power on indicator 4 Heat Demand Indicator illuminates when thermostat demands heat i e oil temperature is more than 5 C below temperature setting Extinguishes when desired temperature is reached 2 3 2 E402F Fryer Control Panel See Figure 3 Figure 3 E402F Control Panel 1 Four Digit LED Display Displays Set temp Actual temp cook time remaining and also used for programming pu...

Страница 5: ...r and ensure that the person s responsible understands the instructions to correctly operate and clean unit in a safe manner Emphasis should be given to safe operation and use of drain valve and oil bucket Oil bucket should not be overfilled to allow safe movement Oil should be allowed to cool before any manual handling Note The oil container may be heavy Drain small amounts at a time if necessary...

Страница 6: ...unplug control panel b Disconnect electrics loom and remove fixings to enable controller to be removed c Carefully replace in reverse order 3 10 MAINS ON and HEAT DEMAND NEONS a Remove control panel by undoing fixings at top and bottom of control panel and unplug control panel b Remove electrical connections from neon Undo neon retention nut c Carefully replace in reverse order 3 11 DRAIN VALVE a ...

Страница 7: ... ordering spare parts always quote the appliance type and serial number This information will be found on the data plate SECTION 5 CRITICAL DIMENSIONS 7 Set to 0 8 Set to 10 minutes Set to F Timer Pump Settings Set for 230V ...

Страница 8: ...e Before operation pan requires to be thoroughly cleaned and dried Discolouration of heated parts is caused by factory testing to ensure unit is satisfactory It will not affect quality or performance All Models An electronic thermostat with temperature probe is fitted The operating thermostat automatically controls oil temperature The temperature limit thermostat ensures that the oil will not reac...

Страница 9: ...ONE will display when cook cycle has ended and alarm will sound If DONE is displayed immediately and alarm sounds key has not been programmed See Section 6 3 2 for programming details b Stop a timing cycle Press and hold an active product key for 3 seconds or press key 3 times within 2 seconds c Respond to a DONE alarm Cancel signal by pressing same product key used to start timing cycle d Multipl...

Страница 10: ...ss temperature key again 6 3 2 Programming a Product Cycle Time and Action Alarm a Press and hold P key for 3 seconds Prog will be displayed Note Programming mode will exit automatically if no keys are pressed within 2 minutes b Select a product key to program 1 to 4 The display will alternate between ti z and X XX where z is the number of the key pressed and X XX is the set time in minutes and se...

Страница 11: ...rect level SECTION 8 CLEANING and MAINTENANCE RECOMMENDATION Personal protective equipment PPE s should be used when cleaning or handling medium within this appliance WARNING NEVER PUMP WATER THROUGH THE FILTRATION PUMP AT ANY TIME Warning The fryer is supplied with castors at rear and should be connected to supply piping by means of a connector for moveable appliances An anti tipping restraint ca...

Страница 12: ...nd dry oil bucket and oil suction pipe 19 Replace strainer and micro filter in oil bucket and return oil bucket to cradle 20 Fill fry pot with clean oil to MIN mark Refer to Section 7 2 SECTION 9 COOKING HINTS Frying food involves many variables and the following information is a guide only 1 Ensure frying medium is clean and free of debris 2 When topping up with oil ensure oil level does not exce...

Страница 13: ...B 36 32 31 25 1 2 3 6 5 4 9 8 7 9 WAY MALE PLUG HOUSING MATE WITH PUMP LOOM 37 36 41 35 44 45 SAFETY CONTACTOR A1 A2 7 9 11 16 30 1 3 5 15 22 A1 15 B1 0 8 10 F 230V PUMP TIMER 34 9 WAY MALE PLUG HOUSING 9 WAY MALE PLUG HOUSING MATE WITH CONTROL PANEL MATE WITH CONTROL PANEL 1 2 3 6 5 4 9 8 7 39 39 40 40 27 27 31 31 19 19 24 33 WIRES 39 40 TO BE FITTED WIRES 39 40 TO BE FITTED TO 9 WAY HOUSING TO 9...

Страница 14: ...Way Female Plug Housing 96 95 COM N O N C COM N O N C J3 J4 J2 9 Way Female Plug Housing G5 FASTRON Controller 91 92 T12 97 Probe T5 T4 T1 T7 T2 T3 Relay T6 95 98 99 82 81 T10 T9 T11 T8 COM 97 99 83 83 82 95 81 96 91 92 Heat On Neon Amber Power On Neon Red 96 E402F Control Panel Wiring Diagram E401F Control Panel Wiring Diagram ...

Страница 15: ...CH SAFETY STAT 29 28 20 1 3 5 L1 L2 L3 7 A2 A1 17 ON OFF SWITCH 5A FUSE 21 2A FUSE 23 FAST CONTROLLER 98 82 99 POWER NEON 24 95 C5 83 HEAT NEON 97 96 C6 19 81 C9 31 PUMP SWITCH 25 91 92 39 40 TO THERMISTOR PROBE C1 C2 M BROWN 36 P5 P7 41 P9 35 37 P1 P3 TO CONTROL PANEL 43 BLUE GR YL CIRCUIT DIAGRAM for E401F 15 ...

Страница 16: ...CH SAFETY STAT 29 28 20 1 3 5 L1 L2 L3 7 A2 A1 17 ON OFF SWITCH 5A FUSE 21 2A FUSE 23 CTT CONTROLLER 24 95 C5 96 C6 19 C9 31 PUMP SWITCH 25 91 92 39 40 TO THERMISTOR PROBE C1 C2 M BROWN 36 P5 P7 41 P9 35 37 P1 P3 TO CONTROL PANEL 43 BLUE GR YL 18 24V TRANSFORMER 26 33 27 C4 C3 94 93 CIRCUIT DIAGRAM for E402F 16 ...

Отзывы: