Lumina 17
Installer
30
Control
Setting of the heating control type:
LINEAR
or
RELAY
.
Output address
Setting of the analog output address (choice
LINEAR
) or relay output address (choice
RELAY
).
Relay type
Setting of the type of relay control.
ON/OFF
or
MODULATING
.
Analog type*
Setting indicating the analog control type
Precontrol
Setting indicating if the heat demand should be transmitted to a central boiler control
(precontrol).
6.2.2
OptiSec-settings
INSTALLER
,
HEAT COOL HUM
, tab page
OptiSec
Band
Setting of the maximum correction (
Band
). The control computer can increase the
setpoint heating until this equals the setpoint house temperature.
Delay
Setting of the
Delay
to minimise the influence of temperature fluctuations.
The control computer only applies the OptiSec-correction, if the actual house temperature
has fallen below the setpoint house temperature during the wait time.
For example, set a wait time of 2 hours. The control computer will only increase the
correction when the actual house temperature has been below the setpoint house
temperature for an uninterrupted period of 2 hours. If the actual house temperature briefly
comes above the setpoint house temperature, the
Delay
will be reset.
The wait time also applies to the decrease of the corrections. The control computer will
only decrease the correction when the actual house temperature has been above the
setpoint house temperature for an uninterrupted period of 2 hours.
Slope time
Setting of the time within which the control computer must complete the required
correction increase or decrease.
Delay cnt
Readout of the already elapsed
Delay
(minutes).
Correction
Readout of the actual correction using OptiSec.