Power On: Press
for 3 seconds to light up screen, then press
to power on heat pump.
2.
Adjust Set Temperature: When screen is unlocked, press
or
to display or adjust the set temperature.
3.
Smart/Silence mode selection:
a.
Smart mode as default will be activated when heat pump is on, and screen shows
.
b.
Press
to enter Silence mode, and screen shows
.
(Suggestion: select Smart mode for initial heating.)
4.
Defrosting
a.
Auto Defrosting: When heat pump is defrosting,
will be flashing. After defrosting,
will stop flashing.
b.
Compulsory Defrosting: When heat pump is heating, press
and
together for 5 seconds to start
compulsory defrosting, and
will be flashing. After defrosting,
will stop flashing.
(Note: Compulsory defrosting intervals should be more than 30 minutes and the compressor should run for
more than 10 minutes.)
5. Temperature display conversion between
℃
and
℉
:
Press "
"
and "
" together for 5 seconds to switch
6. Wi-Fi setting
Please kindly check the last page.
2.3. Daily maintenance and winterizing
2.3.1. Daily Maintenance
Please don’t forget to cut off power supply of the heat pump
➢
Please clean the evaporator with household detergents or clean water, NEVER use gasoline,
thinners or any similar fuel.
➢
Check bolts, cables and connections regularly.
2.3.2. Winterizing
In winter season when you don’t swim, please cut off power supply and drain water out of the
heat pump. When using the heat pump under 2
℃
, make sure there is always water flow.
Important:
Unscrew the water union of inlet pipe
to let the water flow out.
When the water in machine freezes in
winter season, the titanium heat
exchanger may be damaged.
Содержание IPH15
Страница 1: ...Thank you for choosing Fairland Full inverter heat pump INSTALLATION USER MANUAL ...
Страница 2: ......
Страница 18: ...15 FOR INSTALLERS AND PROFESSIONALS APPENDIX 1 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Страница 19: ...16 FOR INSTALLERS AND PROFESSIONALS APPENDIX 2 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...
Страница 20: ...17 FOR INSTALLERS AND PROFESSIONALS APPENDIX 3 HEATING PRIORITY WIRING DIAGRAM OPTIONAL ...