9.5.
390 V to 358 V && 358 V to 390 V at Loading
Test Condition:
Load: 100% load, during the loading-point to change, the PFC bulk voltage steps up to
390 V from 358 V or steps down to 358 V from 390 V.
Test Results:
Input Voltage
Loading (A)
Loading (%)
115 V / 60 Hz 390 V to 358 V
15.37
61.5
230 V / 60 Hz 390 V to 358 V
16.09
64.4
115 V / 60 Hz 358 V to 390 V
17.9
71.6
230 V / 60 Hz 358 V to 390 V
18.7
74.8
9.6.
390 V to 358 V && 358 V to 390 V at Vrms
Test
Condition:
Load: 100%. Load, during the AC input to change, the PFC bulk voltage steps
up to
390 V from 358 V or steps down to 358 V from 390 V.
Test Results:
Loading & Bulk Voltage
Input Voltage
Loading = 100% 390 V to 358 V
235 V
Loading = 100% 358 V to 390 V
253 V
9.7.
Hold up Time
Test Condition:
After AC power off, the output voltages should stay at nominal value for at least 17 ms.
Test Results:
Hold up Time
90
V/60
Hz
264
V/50
Hz
100% Load
50% Load
20% Load
100% Load
50% Load
20% Load
17.09 ms
23.56 ms
66.51 ms
17.61 ms
68.59 ms
134.68 ms
Vbulk 395
V
Vbulk 352
V
Vbulk 352
V
Vbulk 395
V
Vbulk 395
V
Vbulk 395
V
Ch2:
V
AC
, Ch3:
12Vo
, Ch4:
Vbulk
90 V / 60 Hz, 100% Load
264 V / 50 Hz, 100% Load
Figure 20.
Test Waveform of Hold up Time