Single-dr
ives
3.
Ref.2003
· 87 ·
QC-PDS
HARDWARE
Electrical data
T. H3/5
Single-drives.
Size|1.
Width:
78 mm.
Electrical data.
QC-DR-
-F
007
012
021
030
040
055
DC BUS voltage
565-800 V DC
Power to control circuits
24 V DC (between 21 V DC and 28 V DC)
Consumption of the control circuits (24 V DC)
0.7 A
0.7 A
0.9 A
0.9 A
0.9 A
0.9 A
Speed feedback
Encoder
Controlling method
PWM, AC sinewave, vector control
Interface
Inline Ethernet, digital SERCOS-III BUS
Displays the Ethernet interface status
D10/D11 leds
Displays the drive status
LEDs D8/D9 · only for QC-DR-
-
F
models ·
Protections
Over-voltage, over-current, over-speed, heatsink
temperature, CPU temperature, motor temperature,
hardware error, overload.
Min. cross-section (mm²) for the power conductors
according to EN 60204-1, table 6 method B2
*
for
axis / for spindle
0.75/-
0.75/-
1.5/-
2.5/4.0 4.0/6.0 6.0/16.0
Max. allowable cross-section (mm²)
of flexible cable connector
2.5
6.0
16.0
Rated output frequency for X11A
0-550 Hz
**
Current bandwidth
800 Hz
Speed bandwidth
100 Hz · depends on the motor/drive set ·
*
The recommended cross-section depends on the rated operating power of the connected motor.
**
Equal to or higher than 550 Hz, only for QC-DR-...-
MDU
(dual-use).
T. H3/6
Single-drives.
Size|3.
Width:
156 mm.
Electrical data.
QC-DR-
-F
080
120
DC BUS voltage
565-800 V DC
Power to control circuits
24 V DC (between 21 V DC and 28 V DC)
Consumption of the control circuits (24 V DC)
1.2 A
1.2 A
Speed feedback
Encoder
Controlling method
PWM, AC sinewave, vector control
Interface
Inline Ethernet, digital SERCOS-III BUS
Displays the Ethernet interface status
D10/D11 leds
Displays the drive status
D8/D9 leds
Protections
Over-voltage, over-current, over-speed, heatsink
temperature, CPU temperature, motor temperature,
hardware error, overload.
Min. cross-section (mm²) for the power conductors
according to EN 60204-1, table 6 method B2
*
for
axis / for spindle
10/25
25/50
Max. allowable cross-section (mm²)
of flexible cable connector
35
35
Rated output frequency for A19/X11
0-550 Hz
**
Current bandwidth
800 Hz
Speed bandwidth
100 Hz · depends on the motor/drive set ·
*
The recommended cross-section depends on the rated operating power of the connected motor.
**
Equal to or higher than 550 Hz, only for QC-DR-...-
MDU
(dual-use).
Содержание QC-PDS
Страница 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Страница 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Страница 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Страница 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Страница 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Страница 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Страница 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Страница 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Страница 322: ...Connection diagrams 10 CONNECTION DIAGRAMS 322 Ref 2003 QC PDS HARDWARE 322 This page intentionally left blank...
Страница 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Страница 367: ...ANNEXES...
Страница 368: ...ANNEX A1...
Страница 383: ...ANNEX A2...
Страница 398: ...ANNEX A3...
Страница 418: ......
Страница 419: ......