Power supplies
POWER SUPPLIES
Rege
nerative
Pow
er Su
ppli
es
2.
Ref.2003
· 79 ·
QC-PDS
HARDWARE
For configurations 2 and 3, as in figure
When the voltage setpoint of the DC BUS (given by the selected by
switch configuration) and the value of the rectified line voltage
(1.41xVline) are very close to each other, the voltage command of
the bus is adjusted automatically a few volts over the peak voltage of
mains issuing the warning
A706
.
The maximum setpoint limit allowed at the DC BUS is 725 V DC, so
if the auto-adjustment exceeds this value, then the RPS power supply
will prompt the
E707
error code.
Note that lowering the line voltage also lowers the DC bus voltage.
T h e m i n i m u m v a l u e i s d e t e r m i n e d b y t h e s e l e c t e d s wi t c h
configuration.
For configuration 1, as in figure
When the user changes the value of parameter VP5 (650 V DC by
default), when the line voltage approaches the voltage setpoint of the
DC BUS, an
E706
error code is prompted without any automatic
adjustment required. If its default value has not been changed, it will
behave the same way as the rest of the previous configurations.
Push buttons
RESET button
Initialization button on the main power supply. This button allows the user
to return the equipment to the same initial conditions
·
reset
·
after an
anomaly has been noticed.
BOOT button
This button starts the installation/update process of the computer
software via the WinDDSSetup application
·
select the
QCRPS
input in
the “BootType” window after clicking the BOOT icon
·
.
With software version 01.05 or higher, it enables the SERCOS-II
transmission speed to be viewed and edited without having to access the
WinDDSSetup.
Performance in RPS mode
NOTE.
See chapter 14, section
MESSAGE CODES FOR RPS POWER SUPPLIES
of the manual
·
man_dds_soft.pdf
·
regarding the causes of the
prompted errors and/or warnings.
Содержание QC-PDS
Страница 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Страница 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Страница 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Страница 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Страница 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Страница 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Страница 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Страница 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Страница 322: ...Connection diagrams 10 CONNECTION DIAGRAMS 322 Ref 2003 QC PDS HARDWARE 322 This page intentionally left blank...
Страница 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Страница 367: ...ANNEXES...
Страница 368: ...ANNEX A1...
Страница 383: ...ANNEX A2...
Страница 398: ...ANNEX A3...
Страница 418: ......