Page: 52 - Installation Manual - NC-200 PB
<
Kv
>
to set the gain with automatic back-and-forth movements.
·
Select the
or
axis.
Indicate the coordinate of the positive limit,
Indicate the coordinate for the negative limit,
A back-and-forth movement is generated to analyze the dynamic response on
reversal movements. If overshooting occurs, the corresponding Kv factor is
decreased in 5 units at each reversal until achieving a 1st order system without
overshooting in either direction and it sets PAR40 and PAR41 with the
corresponding Kv values. It acknowledges the end of this process with two
beeps.
Pressing
aborts the active movement and increases Kv in 10 units.
This test may be interrupted by pressing
Selecting ">" and pressing
offers three options:
I0s- Testing of the encoder I0's
The 2nd line shows 0's and 1's indicating the level of the encoder I0's for
the X and Y axis from right to left.
Moving the axis slowly by hand, the I0 will be detected with a short blinking.
PULSES- Testing the number of encoder pulses/turn
When selecting the
axis, the 1st line displays "PULSES 1" and when
selecting the
axis, it displays "PULSES 2".
Moving the axis by hand far enough to detect the I0 twice, the 2nd line will
show the number of pulses per turn x PAR01 x PAR02.
DATE
The 1st line shows the software version and the 2nd line its release date,
day, month, year.
To exit to the initial menu, press